Location

The EG2 should be installed in a dry ventilated 

location, where ambient conditions are 

maintained within the requirements of the unit. 

The unit has ventilation slots on its sides to allow 

convection cooling and in no circumstances 

should these be blocked. 

Mounting

Always mount in well ventilated location Allow 

50mm (2”) above and below the unit if trunking 

with a depth greater than 50mm (2”) is used.

Ambient atmosphere requirements

Temperature: +2°C to +40°C (+36°F to +104°F)
Humidity: 5% to 95% non-condensing
IP Rating: IP20

Weight:  

0.25Kg (0.55 lbs)

Dimensions

Introduction

The Ethernet Gateway provides a connection 
between an iCAN network and an Ethernet 
LAN. This allows a user to control and 

configure the iCAN system using iCANsoft on 

a LAN network PC or via the internet rather 
than by connecting directly into iCANnet

TM

Where a wireless LAN is in place (or by 
connecting a wireless router into the Ethernet 
Gateway) the user can access the network 
with a Wi-Fi enabled PC running iCANsoft.
The Ethernet Gateway is also the host for the 
iCAN series of remote applications including 
iOS (iPhone®/ iPod touch®/ iPad®) and a 
webserver front end where applications are 
downloaded separately. Coupling the EG2 to 
a WIFI network enables scene control, visual 

feedback and modification from your hand 

held device.
The Ethernet Gateway also facilitates 
connection to the internet when used with 

iCANsoft, a firewall, ISP and a Ethernet switch, 

this then enables remote connection for 
programming & obtaining diagnostics of the 
lighting control system.
The built in astronomical timeclock feature 
enables preprogrammed timed events for your 
lighting system. 

Summary of Contents for EG-2

Page 1: ...EG 2 Ethernet Gateway Installation Guide ...

Page 2: ...utions EG 2 9850 000776 01 2 Contents Introduction 3 Basic Schematic 3 Installation 3 Product Overview 4 Connecting the Supply 5 iCAN Network Connections 5 Set Up Instructions 6 Configuration 6 Setting the IP address 6 7 ...

Page 3: ...l and configure the iCAN system using iCANsoft on a LAN network PC or via the internet rather than by connecting directly into iCANnetTM Where a wireless LAN is in place or by connecting a wireless router into the Ethernet Gateway the user can access the network with a Wi Fi enabled PC running iCANsoft The Ethernet Gateway is also the host for the iCAN series of remote applications including iOS i...

Page 4: ...error iCAN IDENT Switch that causes the EG2 to send a message on the CAN BUS to identify itself iCAN status Green flashing LED indicates normal operation Product Overview The label on the enclosure identifies the position of the status LEDS switches connectors iCAN Network For connection see Page 5 for wiring details TIMECLOCK Set through iCAN programming software LED on when timeclock active RESE...

Page 5: ...r Consult Cooper Lighting Solutions for information on alternative cable types IMPORTANT NOTE Connecting a mains potential cable to the iCAN Network terminals is likley to damage the unit and others connected and invalidate warranty V 0V CAN L SHIELD CAN H 0V VDC iCAN devices are daisy chained on the network Spurs from the Network are not permitted and will result in communications problems Device...

Page 6: ...ttings are to use a fixed IP address of 192 168 0 100 Any device used to communicate with the EG2 will need to be located within the 192 168 0 x subnet Power up The EG2 takes approximately 60 seconds to be ready for use once power is applied Wait for the Green CAN LED to flash slowly The Green Power LED will double flash continuously while EG2 is on If Ethernet is connected the Link and Data LEDs ...

Page 7: ...ll be required to set the software to communicate using the Ethernet Port This is done by selecting from the Tool bar Tools Options Network Select Ethernet Gateway and change the IP address to 192 168 0 100 Also ensure the Use Password check box is ticked The detault password is Cooper123 Case sentitive Select OK to confirm and set the address The software can now be used to configure any items co...

Page 8: ...RANTY OF MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS No employee agent dealer or other person is authorised to give any warranties on behalf of the Seller or to assume for the Seller any other liability in connection with any of its goods except in writing and signed by the Seller The Seller makes no representation that the goods comply with any present or future federal state or local reg...

Reviews: