ATTENTION Receiving Department:

Note actual fixture description of any shortage or noticeable damage on delivery receipt. File claim for common carrier 

(LTL) directly with carrier. Claims for concealed damage must be filed within 15 days of delivery. All damaged material, 

complete with original packing must be retained.

VRVT3 Description

The VRVT3 LED is a Vaportite fixture using a reinforced fiberglass housing with a high impact diffuser. The fixture is 

suitable for interior and exterior applications and can be surface or chain mounted. The VRVT3 LED has been designed 

for maximum operation in commercial institutional and industrial environments and is suited for ambient temperatures 

of -20°C to 25°C, with some models rated to 55C. It is also rated for wet locations and has IP ratings of IP65, IP66, IP67, 

and IP69.

WARNING

Installation Instructions – VRVT3 LED Vaportight Luminaire Installation
Instructions d’installation – Luminaire DEL étanche à la vapeur VRVT3
Instrucciones de instalación – Instalación de la luminaria VRVT3 LED 

Vaportight

IB519126EN

Fail-Safe

DISCLAIMER OF LIABILITY: Cooper Lighting Solutions assumes no liability for damages or losses of any kind that may 

arise from the improper, careless, or negligent installation, handling or use of this product. 

 

IMPORTANT:

 Read carefully before installing fixture. Retain for future reference.  

NOTICE:

 These instructions do not claim to cover all details or variations in the equipment, procedure, or process 

described, or to provide directions for meeting every possible contingency during installation, operation or maintenance. 

When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your 

nearest representative.

NOTICE:

 Proper grounding is required to insure personal safety. 

NOTICE:

 Fixture may become damaged and/or unstable if not installed properly.

Note:

 Specifications and dimensions subject to change without notice.

Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation and maintenance of this product 

must be performed by a qualified electrician. This product must be installed in accordance with the applicable 

installation code by a person familiar with the construction and operation of the product and hazards 

involved. 
Risk of Fire and Electric Shock- Make certain power is OFF before starting installation or attempting any 

maintenance. Disconnect power at fuse or circuit breaker.
Risk of Fire- Minimum 90°C supply conductors.
Risk of Burn- Disconnect power and allow fixture to cool before handling or servicing.
Risk of Personal Injury- Due to sharp edges, handle with care.
Must be very careful if power tools are used to install the fixture. Uncontrolled torque setting may lead to 

thread/gasket damage or lens breakage.
Failure to comply with these instructions may result in death, serious bodily injury and property damage.

Summary of Contents for Fail-Safe VRVT3

Page 1: ...ture reference NOTICE These instructions do not claim to cover all details or variations in the equipment procedure or process described or to provide directions for meeting every possible contingency during installation operation or maintenance When additional information is desired to satisfy a problem not covered sufficiently for user s purpose please contact your nearest representative NOTICE ...

Page 2: ...d attach to loop hangers Figure2 Modular Surface Mount Option sold separately The modular Surface Mount consists of 2 components a fixture bracket and a surface mounted bracket Attach a fixture bracket to each stud on the back of the fixture using the supplied hex nuts Measure the distance between the two studs and properly space the surface brackets apart on the mounting surface with appropriate ...

Page 3: ...ench when tightening any fitting to the hub Assemble the hub through the housing access hole with the O ring on the outside Thread the hub locknut onto the hub and tighten firmly Do not allow the outside portion of the hub and O ring to rotate when tightening Figure 5 6 For general wet location installations and IP65 IP66 IP67 IP69 use the supplied connector hub and install either a suitably rated...

Page 4: ...t only The remote battery pack is housed separately in a 2ft VRVT housing and connected to the primary unit with a 3ft length of liquid tight conduit and straight fittings with the units pre wired Only the EM unit requires input supply wiring Once in operation and a c power applied connect the 2 red converter connector wires with supplied wire nut The test button indicator light is located in the ...

Page 5: ...rits ni fournir de directives pouvant répondre à toutes les éventualités pouvant survenir pendant l installation le fonctionnement ou l entretien Si des renseignements additionnels sont nécessaires afin de résoudre un problème insuffisamment décrit selon l utilisateur veuillez communiquer avec votre représentant le plus près de chez vous AVIS Une mise à la terre adéquate est requise afin d assurer...

Page 6: ...urface avec module Option vendue séparément Ce montage en surface avec module comprend deux 2 composants un support de luminaire et un support de montage en surface Fixez le support de luminaire sur chaque montant situé derrière le luminaire en utilisant les écrous hexagonaux fournis Mesurez la distance entre les deux 2 montants et espacez les supports de surface de part et d autre de la surface d...

Page 7: ...es raccords au plot Assemblez le plot par le trou d accès du boitier en utilisant un joint torique à l extérieur Vissez le contre écrou du plot au plot et serrez le fermement Évitez tout mouvement de rotation de la partie extérieure du plot et du joint torique lors du serrage Figures 5 et 6 Plot Bague d étanchéité Bague de mise à la terre Corps Garniture d étanchéité Pour des installations général...

Page 8: ...oitier VRVT de 0 6 m 2 pi et raccordée au luminaire primaire avec un conduit étanche aux liquides de 0 9 m 3 pi et des raccords droits aux luminaires préalablement câblés Seuls les appareils de secours nécessitent une entrée d alimentation électrique Dès la mise en service et le courant continu installé raccordez les deux 2 fils rouges connecteur convertisseur avec les deux 2 capuchons de connexio...

Page 9: ...ortar directivas para tratar cualquier posible contingencia durante la instalación el funcionamiento o el mantenimiento Cuando se requiera mayor información para tratar un problema que no está cubierto suficientemente para los fines del usuario contacte a su representante más cercano AVISO Es necesaria una correcta conexión a tierra para garantizar la seguridad personal Observe cuidadosamente el p...

Page 10: ...ular La opción se vende por separado El montaje de superficie modular consta de 2 componentes un soporte de accesorio y un soporte montado en la superficie Fija un soporte de fijación a cada perno en la parte posterior del accesorio utilizando las tuercas hexagonales suministradas Mide la distancia entre los dos pernos y separa correctamente los soportes de superficie en la superficie de montaje c...

Page 11: ...istrado e instala un cable y agarre de cable WT con la clasificación adecuada o un conducto y accesorios herméticos a líquidos Para IP69 usa solo conductos y accesorios herméticos a líquidos Cuando instales el concentrador aplica una pequeña tira de sellador de silicona alrededor de la esquina interna de la junta tórica y el cuerpo del concentrador antes de instalar el concentrador Aplica sellador...

Page 12: ...ipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Énoncé de la FCC Remarque Cet équip...

Reviews: