These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please
contact your nearest representative.

Customer First Center  •  1121 Hwy 74 South  •  Peachtree City, GA  30269

IMI-572    AVU040062

Ascent/Strut Fixtures

Sheet 3 of 5

4/26/04         IMI-572

INSTALLATION INSTRUCTIONS

IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE.

RETAIN FOR FUTURE REFERENCE.

TM

WARNING: 

Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing
or servicing.

7. 

Hook WALL BRACKET over WALL PLATE and place 
SUPPORT BRACKET into SUPPORT HOLES in WALL PLATE
to support fixture as shown. (Fig. 7) 

Make wire connections in WALL BRACKET.
Wire the fixture ground lead to the supply ground lead.
Wire the fixture voltage lead to the supply voltage lead.
Wire the fixture common lead to the supply common 
lead.

NOTE:

To wire to circuits not having a neutral lead (such 

as 480V), connect the fixture voltage lead to one of the
supply leads and the fixture common lead to the other 
supply lead.

8.

Push SUPPORT BRACKET into WALL BRACKET and lower 
fixture until WALL BRACKET fits over WALL PLATE. Tighten 
1/4-20 SOCKET SCREW. (Fig. 8)

NOTE:

Ensure wires are not pinched while closing WALL 

BRACKET to WALL PLATE.

Fig. 7

WALL

BRACKET

SUPPORT

BRACKET

SUPPORT

HOLES

WALL

PLATE

Fig. 8

WALL

BRACKET

SOCKET

SCREW

Summary of Contents for INVUE IMI-572

Page 1: ...ral Upon receipt of fixture thoroughly inspect for any freight damage which should be brought to the attention of the delivery carrier Compare the catalog description listed on the packing slip with the fixture label on the housing to assure you have received the correct merchandise Safety This fixture must be wired in accordance with the national electrical code and applicable local codes and ord...

Page 2: ...pplied and secure GASKET and WALL PLATE to wall with 4 1 2 13 X 1 12 long BOLTS and 4 Lockwashers Fig 5 Torque BOLTS to 450 in lbs NOTE The SPACER WALL BRACKET and associated components and hardware are shipped separately from the fixture 6 Assemble WALL BRACKET to SPACER and HOUSING with 2 BOLTS 2 FLAT WASHERS and 2 LOCK WASHERS by feeding BOLTS through holes in SPACER and into tapped holes in WA...

Page 3: ...fuse or circuit breaker before installing or servicing 7 Hook WALL BRACKET over WALL PLATE and place SUPPORT BRACKET into SUPPORT HOLES in WALL PLATE to support fixture as shown Fig 7 Make wire connections in WALL BRACKET Wire the fixture ground lead to the supply ground lead Wire the fixture voltage lead to the supply voltage lead Wire the fixture common lead to the supply common lead NOTE To wir...

Page 4: ...ll lamp Reinstall DOOR at 20 30 angle to housing ensuring both hinges are engaged Close DOOR ensuring DOOR LATCHES are completely engaged Listen for both cams to click on each latch Fig 9 NOTE Prior to installing the lamp check to make sure lamp is of proper type and wattage Observe lamp manufacturer s recommendations and restrictions regarding lamp operation NOTE Reflector are marked to insure re...

Page 5: ...age of the photocontrol must match the voltage of the fixture FUSING Single fuse is available for use with 120V 277V or 347V fixture Double fuse is available for use with 208V 240V or 480V fixtures MAINTENANCE When maintenance is performed check torque on all fasteners and tighten to specified torque if required CLEANING The reflector and door glass may be cleaned with any suitable non abrasive gl...

Reviews: