PHOTOMETRICS
[Complete IES files available at www.cooperlighting.com]
F O OT CA N D L E TA B L E
Select mounting height and read across for
footcandle values of each isofootcandle line.
Distance in units of mounting height.
Mounting Footcandle Values for
Height
Isofootcandle Lines
A
B
C
D
E
TRU40MXX3S / TRU40MXX4S
20'
3.00 1.50 0.75 0.30 0.15
25'
2.00 1.00 0.50 0.20 0.10
30'
1.38 0.69 0.34 0.13 0.06
F O OT CA N D L E TA B L E
Select mounting height and read across for
footcandle values of each isofootcandle line.
Distance in units of mounting height.
Mounting Footcandle Values for
Height
Isofootcandle Lines
A
B
C
D
E
TRU40MXX3F / TRU40MXX5F
20'
3.00 1.50 0.75 0.30 0.15
25'
2.00 1.00 0.50 0.20 0.10
30'
1.38 0.69 0.34 0.13 0.06
F O OT CA N D L E TA B L E
Select mounting height and read across for
footcandle values of each isofootcandle line.
Distance in units of mounting height.
Mounting Footcandle Values for
Height
Isofootcandle Lines
A
B
C
D
E
TRU40SXX3F / TRU40SXX4F
20'
3.00 1.50 0.75 0.30 0.15
25'
2.00 1.00 0.50 0.20 0.10
30'
1.38 0.69 0.34 0.13 0.06
T R U 4 0 M X X 3 S
400-Watt MH
40,000-Lumen Clear Lamp
Type III Segmented
T R U 4 0 M X X 4 S
400-Watt MH
40,000-Lumen Clear Lamp
Type IV Segmented
T R U 4 0 S X X 4 F
400-Watt HPS
50,000-Lumen Clear Lamp
Type IV Formed
T R U 4 0 M X X 3 F
400-Watt MH
40,000-Lumen Clear Lamp
Type III Formed
T R U 4 0 M X X 5 F
400-Watt MH
40,000-Lumen Clear Lamp
Type V Formed
T R U 4 0 S X X 3 F
400-Watt HPS
50,000-Lumen Clear Lamp
Type III Formed
F O OT CA N D L E TA B L E
Select mounting height and read across for
footcandle values of each isofootcandle line.
Distance in units of mounting height.
Mounting Footcandle Values for
Height
Isofootcandle Lines
A
B
C
D
E
TRU40MXX3SB / TRU40MXXSL
20'
3.00 1.50 0.75 0.30 0.15
25'
2.00 1.00 0.50 0.20 0.10
30'
1.38 0.69 0.34 0.13 0.06
T R U 4 0 M X X S L
400-Watt MH
40,000-Lumen Clear Lamp
SL Spill Light Eliminator
T R U 4 0 M X X 3 S B
400-Watt MH
40,000-Lumen Clear Lamp
Type III Segmented w/ House Side Shield
Summary of Contents for Tribute
Page 1: ...Tribute Area Luminaire ...
Page 3: ......