CEAG Notlichtsysteme GmbH
20
Construction and Function
Assembly and Operating Instructions
Automatic Test System AT-S
+
with STAR
+
Technology
SU S
+
2 x 6 A with STAR
+
Technology
Number of circuits
2
Weight
350 g
Rated current per circuit
6 A
H x W X D (in mm)
107 x 90 x 58
Fuse protection per circuit
10 A
Module width
6 subunits
Max. inrush peak current
250 A
Item no.
400 71 360 350
Max. cable diameter
Circuit outlets:
Feed:
flexible 2.5 mm² with wire
end sleeve and rigid 4 mm²
flexible 4 mm² with wire end
sleeve and rigid 6 mm²
SOU S
+
2 x 4 A with rental current feed and STAR
+
Technology
Number of circuits
2
Weight
625 g
Rated current per circuit
4 A
H x W X D (in mm)
178 x 108 x 60
Fuse protection per circuit
8 AT
Module width
10 subunits
Max. inrush peak current
250 A per circuit
Item no.
400 71 360 461
Max. cable diameter
flexible 2.5 mm² with wire
end sleeve and rigid 4 mm²
Summary of Contents for Ceag AT-S+ C0