Applications:

  

Features:

 

Allows selections of speaker zones via a telephone 
keypad (DTMF tones)

• 

One SP4-TZC (controller) can control up to 17 

 

SP4-APS (splitters)

• 

Telephone page input connects to stand alone 
telephone, unused CO port, page port

• 

USB connection for logical zone grouping and 

 

BGM programming (supports Windows 2000 and 
Windows XP)

• 

Up to 9 logical zones, (a logical zone is a user 
selected group of up to 5 zones, individual or fixed)

• 

RS-485 digital control to the SP4-APS speaker 
splitters

• 

Connects to the SP40S or SP40/2 via the BGM input

• 

The combination of 1 SP4-TZC (controller) and up to 
17 SP4-APS (splitters) can provide:

•    Connects to the SP40S or SP40/2 to control  selectable  
 

paging and background music (BGM)

• 

Ability to access individual or multiple speaker zones  

 

throughout the SP40S or SP40/2 system via the telephone 

Addressable Paging Splitter 

and Telephone Zone Controller

SP4-APS 

 

Addressable Paging Splitter

SP4-TZC  

Telephone Zone Controller

Class B  

 

 

 

 

4 zones per splitter 

 

 

 

Up to 68 individual zones (17 splitters)   
17 fixed zones (groups of 4)  

 

 

9 logical zones    

 

 

 

Class A
2 zones per splitter
Up to 34 individual zones (17 splitters)  
17 fixed zones (groups of 2)
9 logical zones

SP4-TZC Telephone Zone Controller:

• 

Connects to the SP40S or SP40/2

• 

Auto programmable

• 

Custom user programmable (for logical zones) 

• 

All call or selected zone(s) telephone paging

• 

Background music (BGM) zone(s) selectable  

• 

Telephone input and background music (BGM)

 

input

• 

Enclosure for the SP4-TZC (controller):

 

 

Dimensions: 13”H x 7.6”W 
x 2.15”D  

 

 

Color: Black

 

 

Wall mountable

• 

Requires 24 VDC, model RPS-2406

SP4-APS Addressable Paging Splitter:

• 

Addressable speaker zone splitter

• 

Mounts inside the SP40S, SP40/2, SPB-80/4, 

 

SPB-160 or SPB-320

• 

Operates on 24 VDC, supplied by the SP40S, 

 

SP40/2, SPB-80/4, SPB-160, SPB-320

• 

Handles 40 watts of supervised audio per zone

• 

UL Standard 864, 9th edition listed 

Model

Order 

Code

Description

SP4Z-APS

9920

Addressable Paging Splitter

SP4-TZC

9921

Telephone Zone Controller

TZC-USB

9923

SP4-TZC Programming Cable 

Ordering Information:

10

Summary of Contents for SAFEPATH SP4Z-A-B

Page 1: ... B Speaker Audio Splitter 5 SAFEPATH 4 Audio Boosters 6 7 System Diagram 8 9 SAFEPATH 4 Addressable Paging Splitter and Telephone Zone Controller 10 SAFEPATH 4 Supervised Volume Control and Remote Microphone 11 Remote Microphone Expansion Module 12 Description Page SP40S SPRM SP4Z A B SP SVC SP4 TZC 151 92 E S5361 6911 0785 157 SPB 80 4 SPB 160 SPB 320 SP4 APS ...

Page 2: ... pagers for private alerting of emergency trouble conditions System Activation Contact closure message activation Approvals Compliance Approvals UL Standard 864 9th edition UL Standard 1711 California State Fire Marshal CSFM New York City MEA FCC Part 15 OSHA 1910 165 and ADA Compliant 3 Year Warranty Made in the USA Background Music Capable of broadcasting from a supplied BGM source Unique superv...

Page 3: ...or Remote Microphone connection Installation Maintenance Multiple trouble LED indicators for quick system diagnostics Fully supervised circuitry always in effect even during BGM and general paging via patent pending technology Removable quick connect disconnect terminals for ease of wiring accepts 12 to 22 AWG Power limited circuitry with Class B or Class A wiring Class A only with use of Audio Sp...

Page 4: ...tention please A fire emergency has been reported in the building While this is being verified please leave the building by the nearest exit Do not use the elevators 2 Fire do not use elevators Female Three 3 rounds of code 3 horn followed by May I have your attention please A fire emergency has been reported in the building While this is being verified please leave the building by the nearest exit Do...

Page 5: ...ither 25V or 70 7V RMS Mounts inside the enclosure of the SP40S SP40 2 or Audio Boosters Power and Trouble LED s Individual zone short and open LED indication Capable of detecting wiring faults Removable wiring terminals for quick connect disconnect accepting 12 22 AWG All output circuitry is Power Limited Space provided to allow for naming of the zones Powered by 24VDC supplied by the either the ...

Page 6: ... achieved Additional strobe power can be obtained via a combination of SPB 80 4 or Wheelock Power Supplies Chargers Power Supply Batteries Fully supervised patent pending circuitry always in effect even during BGM Power limited circuitry Class D amplifiers Internal battery charger and power supply Required batteries fit inside the enclosure sold separately SPB 320 requires four 12 VDC 12 AH batterie...

Page 7: ...150 160 Watt Supervised Audio Power Booster Two 80 watt circuits 220 VAC input black enclosure SPB 80 4 8988 80 Watt Supervised Audio Power Booster with 4 Amps of Supervised and Synchronized Strobe Power Two 2 Amp circuits red enclosure SPB 80 4 B 9931 80 Watt Supervised Audio Power Booster with 4 Amps of Supervised and Synchronized Strobe Power Two 2 Amp circuits black enclosure SPB 80 4E 6147 80...

Page 8: ...elock Strobe Power Supplies SP40S Supervised Multi Function Communication System SPB 80 4 80 Watt Audio Booster 4 Amps of Strobe Power SPB 160 160 Watt Audio Booster SPB 320 320 Watt Audio Booster SPRM Remote Microphone SP4 RMX Remote Microphone Expansion Module SP4 TZC Telephone Zone Controller SP4 APS Addressable Paging Splitter SP4Z A B Speaker Splitter SP4 SVC Supervised Volume Control Strobe ...

Page 9: ... SPB 160 SP4Z A B SP4 APS SPB 320 SP4 APS SP4Z A B SPB 160 SP4 APS SP4 APS Wheelock Strobe Power Supply Wheelock Strobe Power Supply SP4 APS SP4 APS SPB 320 SP4 APS SP4 APS SP4 APS SP4Z A B SPB 160 SP4 APS SP4 APS V V V ...

Page 10: ...ing Splitter SP4 TZC Telephone Zone Controller Class B 4 zones per splitter Up to 68 individual zones 17 splitters 17 fixed zones groups of 4 9 logical zones Class A 2 zones per splitter Up to 34 individual zones 17 splitters 17 fixed zones groups of 2 9 logical zones SP4 TZC Telephone Zone Controller Connects to the SP40S or SP40 2 Auto programmable Custom user programmable for logical zones All ca...

Page 11: ...rent Standby 26mA Alarm 38mA Audio output level 1 05V RMS 6 wire connection to the SP40S SP40 2 or SP4 RMX Mounting plate is red and measures 8 3 4 x 5 fits into a 4 gang back box All output circuitry is Power Limited SAFEPATH 4 Remote Microphone 11 Applications Features Model Order Code Description SP SVC 9926 Supervised Volume Control for use with the SAFEPATH 4 system Ordering Information SAFEPA...

Page 12: ...en the SP4 RMX is connected to the SP40S or SP40 2 the entire system benefits from the additional microphone capability Can be connected to Audio Boosters for general non alarm paging with use of SPRM GP UL Standard 864 listed OSHA 1910 165 ADA and UFC compliant Multiple on board diagnostics with 3 status conditions standby alarm and trouble Operates on 24 VDC supplied by the SP40S SP40 2 SPB 80 4 ...

Page 13: ...its SPB 160 8989 160 Watt Supervised Audio Power Booster Two 80 watt circuits red enclosure SPB 160 B 9930 160 Watt Supervised Audio Power Booster Two 80 watt circuits black enclosure SPB 80 4 8988 80 Watt Supervised Audio Power Booster with 4 Amps of Supervised and Synchronized Strobe Power Two 2 Amp circuits red enclosure SPB 80 4 B 9931 80 Watt Supervised Audio Power Booster with 4 Amps of Supe...

Page 14: ...shall be made in the USA Approvals for the system shall include UL Standard 864 9th edition UL Standard 1711 FCC part 15 California State Fire Marshal CSFM and New York City MEA The system shall be OSHA 1910 165 and ADA compliant 3 Year Warranty SAFEPATH 4 Audio Boosters The Wheelock SPB 320 SPB 160 and SPB 80 4 Audio Boosters shall be NFPA compliant supervised audio and supervised 24VDC synchroni...

Page 15: ...odules and shall be capable of addressing all zones at once All Call a maximum of 68 separate zones 17 fixed zone groups and 9 programmed logical zone groups This shall be accomplished using two digit DTMF tones from a page port an unused CO port or a stand alone telephone with a loop start circuit Also the SP4 TZC shall be able to select zones for background music The SP4 TZC has the following inp...

Page 16: ...o the SP40S or SP40 2 and shall have the capability of providing the SP40S or SP40 2 with up to six system wide All Call Remote Microphone SPRM modules The SP4 RMX can be programmed to provide either priority override for each SPRM module input or First In First Out First In First Out allows the active SPRM to complete its communication before another SPRM can be used All output circuitry shall be...

Reviews: