V5 Home Installation and Operation Manual
7
Notes:
①
Conduct thermal insulation for refrigerant copper tube; in order to ensure the using effect, thickness of
thermal insulating material should not be less than 8mm.
②
Make sure that the refrigerant copper tube is sealed up without leakage.
5.1.5 Installation Requirements for Water System
(
1
)
Connect cooling water inlet of pressure bearing water tank to tap water pipe, connect
hot water outlet to terminal water using outlet.
(
2
)
Tap water inlet should connect to one-way valve and filter.
(
3
)
For easy maintenance, water inlet and water outlet should be installed with manual
cut-off valve.
(
4
)
Install air release valve in the highest point of water pipe.
5.1.6 Installation Method of Hot Water Converter
Wall-mounted installation:
(
1
)
Install wall-mounted board
Fig. 5.3
Notes:
①
Use line aligning method or leveling instrument to find the level position;
②
Use screws to fix the wall-mounted board on the wall after being processed (such as be embedded with
plastic particles);
③
After installing the board, check if it is firmly installed.
(
2
)
Hang the hot water converter on the wall-mounted board