turn off the alarm sound.
3. When alarm sound over 1 minute, the system will be stop, the unit come back
original state.
4. When the system is triggered, the unit will not receive other trigger, until 1 minute
the unit will be triggered.
When the unit into arm state, press any key will not be operation.
5.When the unit is set ARM mode, channel switch time is 2 sec.
■
BACK VIEW
1. AUDIO: Audio Output
2. VIDEO: Video Output
3. ALARM OUTPUT: Connect Siren Or Trigger Box
4. DC12V: Power DC12V Input
5. ANT: Antenna
MONITOR
VCR
SIREN
AUDIO VIDEO
ALARM OUTPUT
ANT
DC 12V
COM NC NO
1
2
3
4
5
ADAPTOR
■
SPECIFICATION
ITEM 15-2400SR
CHANNEL
CH1 CH2 CH3 CH4
FREQUENCY
2413MHz 2432MHz 2451MHz 2470MHz
IMPEDANCE OUTPUT
50
Ω
POWER DC
12V
CURRENT 430
mA
VIDEO OUTPUT
1Vp-p Composite (75
Ω
)
AUDIO OUTPUT
2Vp-p Max
DIMENSION 163×36×138
■
PACKING
1 Receiver
×1
2 User Manual
×1
3 AV Cable
×1
4 Connecter Adaptor
×1
5 Power Adaptor
×1
*CAUTION FOR INSTALLATION
1. Avoid places where there is direct sunlight.
2. Be careful; never let any water in this equipment.
3. The unit does not install in dust or wet environment.
4. Be extra careful not to shake it.
5. Avoid places where temperatures exceed 50
o
C or more.