54
hexadecimal bytes of 01, 20, 00, AB and CD. If the command string is composed of two or more
commands, a comma ‘,’ should be inserted to separate each command. Each comma represents 200
milliseconds. For instance, a command to pan left may be “01000305” and a command to stop panning
may be “01000300”. The user may edit the applicable command as “01000305,01000300” in the “
Move
Left”
field. This means the camera will pan left for 200 milliseconds. The maximal length of a command
string is 60 which is equivalent to 30 hexadecimal bytes. When everything is set, click on
to save
the commands and click on
to close the command setting window.
WebCam provides five more custom commands other than general pan, tilt functions. Administrators can
click on
and refer to the instruction manual of the attached device to setup
frequently used functions. The "
Command
" should be entered in ASCII format alike the pan, tilt
commands. "
Display string
" is for those texts on command buttons and should be less than 8 characters.
To enter more commands or commands other than pan and tilt, a flexible URL is provided for customized
interface. See the “Clear data path for proprietary commands” section in Advanced functions for details.