1.  DESCRIPTION AND FEATURES

1.01

This Data Sheet describes installation of the 
HiGain HRE-421 Mounting Enclosure for

HRU-412 Remote Units.

1.02

Revision—05, August 15, 1995

a) Corrected CLEI Code and Part no.

b) Revised document format.

1.03

This document is part of a set. Refer to the 
Description and Application Technical

Practice #125-800-100 for additional information on
the HiGain System and to #150-412-100 for
information on the HRU-412 remote unit.

1.04

The PairGain HRE-421 shelf houses one 
HRU-412, has a Lexan front cover, and is wall

or desk  mountable. The unit consists of a wall mount
section and a cover which slides over and is attached
to the wall mount section. The wall mount section has
the 400-type connector that accepts the HRU 412.  It
also contains a 14-position terminal block, TB1, for
access to all interface signal connections, an RJ-48C
List 1) or RJ48X (List 2) connector for connecting DS1
leads and a DB9 RS-232 jack (J2) for telco access to
the HIGAIN maintenance test system. A 2 position
terminal block TB2 ,for access to local 48 V  power
and circuit ground, and a 48 V (1 amp) fuse are
provided for the HRU-412, List 7 which can be locally
powered.  A rear panel punch-out labeled LEC (Local
Exchange Carrier) provides cable routing to these
inner connectors. The cover, which has the Lexan end
plate, slides over the wall mounted section and is
secured to it with a screw.

2.  CERTIFICATION

2.01

UL Listing: The HRE-421 is a UL Listed 
component. Use normal caution when

installing or modifying telephone lines. Dangerous
voltages may be present. It is also considered
imprudent to install telephone wiring during a lightning
storm. Always disconnect all telephone lines and
power connections from wall outlets before servicing
or disassembling this equipment.

2.02

Refer to the installation section of the 
appropriate instruction manual for the unit you

are installing for:

• 

Cabling information

• 

Proper connections

• 

Grounding information

• 

Line vs. local power

All wiring external to the product(s) should follow the
provisions of the current edition of the National
Electrical Code.

2.03

CSA Certification: The HRE-421  has been 
tested and found to comply with CSA

Standard C22.2 -950 with telecommunication
features.

3.  WARRANTY

3.01

PairGain Technologies warrants this product 
to be free of defects and to be fully functional

for a period of 36 months from the date of original
shipment, given proper installation and regular
maintenance. PairGain will repair or replace any unit
without cost during this period if the unit is found to be
defective for any reason other abuse or improper use
or installation.

3.02

This module should not be field repaired. If it 
fails, replace it with another unit and return

the faulty unit to PairGain for repair. Any modifications
of the unit by anyone other than an authorized
PairGain representative will void the warranty.

3.03

If a unit needs repair, call PairGain for a 
Return Material Authorization (RMA) number

and return the defective unit, freight prepaid, along
with a brief description of the problem, to:

PairGain Technologies, Inc.
14402 Franklin Avenue
Tustin, CA 92680
ATTN: Repair and Return Dept.
(714)-832-9922
(800) 638-0031

3.04

PairGain will continue to repair or replace 
faulty modules beyond the warranty program

at a nominal charge.  Contact your PairGain sales
representative for details and pricing.

Summary of Contents for PairGain HiGain HRE-421

Page 1: ...rGain 150 1125 01 CLEI T1MFFB04RA List 2 PairGain 150 1125 02 CLEI T1MFFC04RA CONTENTS PAGE A PRODUCT OVERVIEW 1 GENERAL 2 2 CERTIFICATION 2 3 WARRANTY 2 4 TECHNICAL ASSISTANCE 3 B INSTALLATION 5 LIST OF MATERIAL 3 6 MOUNTING 3 7 WIRING 3 8 TURN UP 4 CAUTION This product incorporates static sensitive components Proper electrostatic discharge procedures must be followed Figure 1 Left and right view...

Page 2: ...t It is also considered imprudent to install telephone wiring during a lightning storm Always disconnect all telephone lines and power connections from wall outlets before servicing or disassembling this equipment 2 02 Refer to the installation section of the appropriate instruction manual for the unit you are installing for Cabling information Proper connections Grounding information Line vs loca...

Page 3: ...test jacks etc on the left Lift the cover off the mounting plate and use it as a template for drilling or locating mounting holes Attach the plate securely to the wall 7 WIRING 7 01 Power and Grounding See Figure 4 Attach earth ground to FRAME GND if local practice dictates Terminals 3 8 of TB1 are connected to pins 7 8 S S1 respectively of J3 in Figures 5 6 They are used to terminate the shields ...

Page 4: ...2 wiring is shown in Figure 7 J2 is configured as an RS 232 DTE port TD and RD are the names assigned to the pins per this RS 232 standard The signal on RD is an input to HiGain That on TD is an output from HiGain The port requires only pins 2 3 and 5 to be connected Typical connections to both DB 9 and DB 25 DTE terminal connectors are shown in Figure 7 J2 provides access to a local diagnostic te...

Page 5: ...Section 100 421 100 Revision 05 Page 5 Figure 3 Component Locations Figure 4 TB1 pin assignments ...

Page 6: ...sion 05 Page 6 Figure 5 List 1 RJ 48C Pin Assignments Figure 6 List 2 RJ 48x Pin Assignments Figure 7 RS 232 Pin Assignments Copyright 1995 PairGain Technologies Inc PairGain and HiGain are trademarks of PairGain Technologies ...

Reviews: