background image

Section 100-421-100
Revision 05

Page 4

7.04

Current feed jumpers: See Figure 4.

List 1 & 2 HRU Connections: When the List 1 
or 2 HRU-412 is being inserted into the HRE-

421,  jumper TB1 terminals 11 through 14 as required
by the service order to provide none, 23 mA or 60 mA
current feed toward CPE over the DS1 leads.

List 3 ,4, 6 and 7 HRU Connections: When
the List 3, 4, 6 or 7 HRU-412 is being inserted

into the HRE-421,  TB1 is not required to set the CPE
current.  For these units the CPE simplex terminal
must be left vacant.  This allows switch S2 located on
the card edge connector at the back of these units to
set the current either 60 or 0 mA., as required by the
service order.

7.05

RS-232 Connections: Connector J2 wiring is
shown in Figure 7. J2 is configured as an RS-

232 DTE port. TD and RD are the names assigned to
the pins per this RS-232 standard. The signal on RD
is

an input to HiGain. That on TD is an output from
HiGain. The port requires only pins 2, 3 and 5 to be
connected. Typical connections to both DB 9 and DB
25 DTE terminal connectors are shown in Figure 7. J2
provides access to a local diagnostic terminal.

8.  TURN UP

8.01

Refer to the PairGain Technical Practice 
Section of the unit being installed150-412-100

for complete  instructions.  The HRU card slides into
the two card guides as shown in Figure 3.  It should
be seated firmly  in the connector.  Upon  initial turn
up, all LEDs will momentarily light.  If all equipment is
installed and working, and the DS1 signal is being
transmitted, the system will cold start within about 15
seconds.  No further action is required if all alarms
clear.

Figure 2.  Wall Mounting.

Summary of Contents for PairGain HiGain HRE-421

Page 1: ...rGain 150 1125 01 CLEI T1MFFB04RA List 2 PairGain 150 1125 02 CLEI T1MFFC04RA CONTENTS PAGE A PRODUCT OVERVIEW 1 GENERAL 2 2 CERTIFICATION 2 3 WARRANTY 2 4 TECHNICAL ASSISTANCE 3 B INSTALLATION 5 LIST OF MATERIAL 3 6 MOUNTING 3 7 WIRING 3 8 TURN UP 4 CAUTION This product incorporates static sensitive components Proper electrostatic discharge procedures must be followed Figure 1 Left and right view...

Page 2: ...t It is also considered imprudent to install telephone wiring during a lightning storm Always disconnect all telephone lines and power connections from wall outlets before servicing or disassembling this equipment 2 02 Refer to the installation section of the appropriate instruction manual for the unit you are installing for Cabling information Proper connections Grounding information Line vs loca...

Page 3: ...test jacks etc on the left Lift the cover off the mounting plate and use it as a template for drilling or locating mounting holes Attach the plate securely to the wall 7 WIRING 7 01 Power and Grounding See Figure 4 Attach earth ground to FRAME GND if local practice dictates Terminals 3 8 of TB1 are connected to pins 7 8 S S1 respectively of J3 in Figures 5 6 They are used to terminate the shields ...

Page 4: ...2 wiring is shown in Figure 7 J2 is configured as an RS 232 DTE port TD and RD are the names assigned to the pins per this RS 232 standard The signal on RD is an input to HiGain That on TD is an output from HiGain The port requires only pins 2 3 and 5 to be connected Typical connections to both DB 9 and DB 25 DTE terminal connectors are shown in Figure 7 J2 provides access to a local diagnostic te...

Page 5: ...Section 100 421 100 Revision 05 Page 5 Figure 3 Component Locations Figure 4 TB1 pin assignments ...

Page 6: ...sion 05 Page 6 Figure 5 List 1 RJ 48C Pin Assignments Figure 6 List 2 RJ 48x Pin Assignments Figure 7 RS 232 Pin Assignments Copyright 1995 PairGain Technologies Inc PairGain and HiGain are trademarks of PairGain Technologies ...

Reviews: