15
If the drivers do not qualify by SMART CHECK , the drives will be rejected by
the duplicator.
9.16
SMART WARNING
The SMART WARING option allows you to configure the system check the
disk with S.M.A.R.T. function in different level [0] ,[1],[2].
That detects and reports on various indicators of drive reliability, with the intent
of enabling the anticipation of hardware failures before copy.
Level [0]:
S.M.A.R.T. data indicates a possible imminent drive failure, may
only notify the user and keep going copy.
Level [1]:
S.M.A.R.T. data indicates a possible imminent writing error only,
the system will reject this drive and then copy another.
Level[2]: Whatever S.M.A.R.T. data indicates any error, the system
will reject this drives.
9.17
BTN. SOUND
Disable/Enable key bee sound.
9.18
SHOW EXE TIME
The SHOW EXE TIME option allows you to enable or disable whether the total
execution time for an operation is displayed on the LCD screen. The total
execution time will be displayed after an operation has completed.
Enabled. The total execution time is displayed.
(*)Disabled (default). The total execution time is not displayed.
9.19
SHOW BINAEY BASE
Show Binary Base, it allows to show device’s capacity from Decimal to Binary.
Summary of Contents for MFD-12
Page 7: ...5 5 2 MFD12 BACK VIEW ...