7)  Calibration function: 

Calibrate the accuracy of the channel by calibration 

function.  Click  ‘Calibrate  1ml’,  and  this  channel  will 

output  about  1ml  liquid.  Please  input  the  actual 

output volume (may be not 1ml) in the text box. Then 

click "ok" button.   

Attention:   

Using  the  Calibrate  continaer  to  test!   

When  you  Press  CH1,  Calibrateion  10ML,  when  it 

dosing 9ML. Input the value 9ML it will auto Save

 

 

     

 

 

8)  Connect to the home Wi-Fi   

Click  "Home  Wi-Fi", select  the corresponding  Wi-Fi 

signal.  Input  the  password  and  click  "OK".  The 

application  will  automatically  exit  after  the  phone 

connecting to the home Wi-Fi. Wait for a few minutes 

and reopen the application to search the equipment. 

     

       

Note:Different kinds of route models may affect the 

home  network  function.

 

If  the  equipment  can’t  be 

found, please  reopen  the  application,  or long press 

the  WI-FI  reset  button  for  8  seconds.  The  Wi-Fi 

function will recover to original factory settings.

 

 

Maintenance and Trouble Shooting 

 
1.Which phone model does not support? 
 
Answer:  For  unknown  reasons,  very  few  model  of 
android phones can’t search the equipment, but the 
mainstream mobile phones have been supported. 
 
2.How  do  I  know  whether  the  dosing  pump  works 
properly? 
 
Answer: The blue light flashes once per second. 
 
3.Why it didn’t execute automatically when I modify 
the time to test the dosing? 
 
Answer:  You’re  suggested  to  test  the  dosing 
manually  when  you  first  use  it.  If  four  dosing 
channels all have reaction, it means that the system 
is under stable operation. For the automatic control 
function, we add the safer automatic protection when 
we developed our system. 

(1)After you submit your automatic control schedule, 
the system will not execute the control immediately 
that you change for preventing the situation. The 
system executes the dosing immediately due to the 
artificial operation error. 

(2)If you had executed the dosing once in within one 
hour, you will not be able to change control time 
schedule in that hour for preventing the system 
repeat dosing at the same time due to power cut and 
restore or users’ wrong operation. 

4.

 

Will  the  dosing  stop  operation  for  the 

disconnection of mobile phone or Wi-Fi?   
 
Answer:  NO.  Mobile  phone  App  and  the  dosing 
system  are  working  independently.  Even  if  the 
mobile  phone  is  disconnected  with  the  dosing  or 
WI-FI, the dosing can work independently according 
to the parameters setting previously.     
 
5.

 

Do I need to calibrate the pump due to the power 

cut?   
Answer:  NO.  because  once  you  submit  the  dosing 
data, it will be saved in the dosing equipment. 

 

6.How to reset the Wi-Fi mode? 

Answer: Please long press the button which on the 

back of the dosing. 

 

7. How to Hardware Reset? 

Answer: Hold 8 second for the Reset Button   

 
Notes: 

1.

 

Do not use the dosing in damp environment. 

2.

 

Do  not  drop  the  power  equipment  into  the 

water. 

3.

 

System  Developer  have a  right for upgrade 

the apps without notice 

WEEE

 

 

EU  Waste  Electrical  and  Electronic  Equipment  (WEEE)  Directive  In  August  of  2005, 

the European Union (EU) implemented the EU WEEE Directive 2002/96/EC and later 

the  WEEE  Recast  Directive  2012/19/EU  requiring  Producers  of  electronic  and 

electrical  equipment  (EEE)  to  manage  and  finance  the  collection,  reuse,  recycling 

and  to  appropriately  treat  WEEE  that  the  Producer  places  on  the  EU  market  after 

August  13,  2005.  The  goal  of  this  directive  is  to  minimize  the  volume  of  electrical 

and  electronic  waste disposal  and to  encourage  re-use  and recycling  at the  end  of 

life.  {Coral  Box}  has  met  its  national  obligations  to  the  EU  WEEE  Directive  by 

registering  in  those  countries  to  which  {Coral  Box}  is  an  importer.  {Coral  Box}  has 

also  elected  to  join  WEEE  Compliance  Schemes  in  some  countries  to  help  manage 

customer returns at end-of-life. If you have purchased {Coral Box}-branded electrical 

or electronic products in the EU and are intending to discard these products at the 

end of their useful life, please do not dispose of them with your other household or 

municipal  waste.  {Coral  Box}  has  labeled  its  branded  electronic  products  with  the 

WEEE  Symbol  (figure  1)  to  alert  our  customers  that  products  bearing  this  label 

should not be disposed of in a landfill or with municipal or household waste in the 

EU.  Instead,  please  be  aware  that  {Coral  Box}  is  making  a  return  and  collection 

system  available  to  you,  free  of  transportation  and  recycling  costs,  for  discarding 

these  products.  [Can  only  be  used  by  the  Company  if  this  document  is  publicly 

available]  For  a  copy  of  {Coral  Box}'s  Selective  Treatment  of  Waste  Electrical  and 

Electronic  Equipment  outlined  under  Articles  14  and  15  and  Annex  VII  of  the  EU 

WEEE  Directive  2012/19/EU,  please  click  here  WEEE  Selective  Treatment  List  and 

the list of hazardous materials used in our product 

 

Reviews: