background image

- 3 - 

 

Connecting the Softener.  

Once you have completed the installation of the valves set the valves as follows:  
Softener Inlet and Outlet valve CLOSED 
Bypass valve OPEN 
You can now safely return the stop cock to the open position. Using the hoses provided (if 
installation kit ordered) connect the straight end of the hose having first inserted the washer 
provided to the softener inlet and outlet valves. Connect the angled end to the Softener. The 
Softener inlets and outlets should be indicated either with the words inlet or outlet or with an 
embossed directional arrow on the Softener tails. Normally the Softener tails are in a 
configuration of three with the centre normally being the waste outlet.  

Waste Pipe Installation.  

Connect the waste pipe to the waste outlet on the Softener and run the hose to either an up 
stand or outside drain, a minimum air gap of 20mm must exist at the end of the drain line. 
Softened water will have no adverse effect on a septic tank. Should you need to extend the 
drain hose this can be done by connecting to a 15mm copper tube for a maximum run of 8 
meters with a minimum daytime pressure of 40 psi. Ensure that the drain hose is not kinked 
or obstructed in any way as this will lead to an overflow of the softener. The drain pipe can 
run uphill to a maximum of 1 Meter with a minimum water pressure of 40 psi.       

Summary of Contents for 613

Page 1: ... 1 Soft 001 ...

Page 2: ... drain and the Softener should be as short as possible Ensure that both the drain and overflow will not freeze or reach a temperature above 40 C If putting the Softener within a cupboard ensure that the base is adequately supported If the Softener is being installed within your loft etc it is recommended to house the Softener within a tank capable of storing at least 100 Litres with an overflow fi...

Page 3: ...n the Softener tails Normally the Softener tails are in a configuration of three with the centre normally being the waste outlet Waste Pipe Installation Connect the waste pipe to the waste outlet on the Softener and run the hose to either an up stand or outside drain a minimum air gap of 20mm must exist at the end of the drain line Softened water will have no adverse effect on a septic tank Should...

Page 4: ...litres of water into the brine tank You may also at this point put a quantity of salt into the tank Do not allow the salt level in the brine tank to exceed the height of the overflow The amount of salt used will depend on the type and model of Softener you have you should never let the brine tank become completely empty of salt and it is advisable to check the salt levels on a regular basis until ...

Page 5: ...he display should show 255 on occasions the display may flash between time and regeneration with the regen symbol flashing press set button to clear During the set up process the display may revert to service mode after 25 seconds by repeatedly pressing the set button you can scroll to the part of the set up programme you require If you receive an ERR3 message allow the cam shaft to turn for a few...

Page 6: ...dant on the model you have and has been pre set at the factory Typically set on H for 10L S for 15L Press the set button to advance to the next setting The following will then be displayed A number with Kg after will appear on the display This figure will be pre set at the factory Press the set button again to advance to the next setting The following will then be displayed Setting the Hardness Pr...

Page 7: ... gone and the glass chamber is full press the set button and up arrow to move the cycle onto C0 service position Finally turn on a tap after the softener until the water runs clear Your softener is now ready to supply your property with soft water Please bear in mind that it may take some time for soft water to reach all outlets in your home It is advised that you instigate a delayed regeneration ...

Page 8: ...t the Control Only to be done when necessary 1 Press and hold SET and DOWN together for 5 seconds 2 H0 and the system s resin volume for model will be displayed 3 Press and hold the square set button for 5 seconds three dashes should then appear on screen 4 Use the up or down arrows to select the correct or nearest media volume of your softener 5 Press the set button to accept this setting 6 Refer...

Reviews: