- 6 -
Press the set button to accept this setting and again to the next setting.
The following will then be displayed.
Set Days to Regenerate (760 Metered units only).
This setting is a default override setting to allow for optimum performance
of the resin it should be regenerated at least every 7 – 10 days, this will
then perform a regeneration of the softener should one not have been
instigated during this time period. Press the set button to make the display
flash, use the up and down arrows to advance to the required setting then
press the set button to confirm.
(740 Timer units only)
Use this setting to set the frequency of
regeneration. The following will then be displayed.
This display will show one of the following letters S, L or H. This is
dependant on the model you have and has been pre-set at the factory.
(Typically set on H for 10L & S for 15L)
Press the set button to advance to the next setting.
The following will then be displayed.
A number with Kg after will appear on the display. This figure will be
pre-set at the factory.
Press the set button again to advance to the next setting.
The following will then be displayed.
Setting the Hardness.
Press the set button and the display will flash, use the up and down arrows
to enter the water hardness in ppm then press the set button to confirm the
setting.
The display should then revert to the time display.
Once you are satisfied that the Softener is both plumbed in and set up
correctly it is ready for commissioning.
Normal Valve Operation
During normal valve operation the 740 will display the time of day.
The 760 will alternate between the time of day and the volume of water
remaining in cubic meters before the system will need to regenerate.