background image

3

a: 

Place wall channels on the tray ensuring they are vertical and a minimum of 3mm back from the front of the tray. Place masking tape against 

the wall before marking drill hole positions, this will help prevent the drill bit slipping. Drill 6.5mm holes, 30mm deep and insert the wall plugs. 

b: 

Apply sealant to the back of the wall channels. 

c: 

Place the wall channels onto the door. 

ø 6.5

mm

4

a

b

c

3mm

min

10mm

ø 3

mm

5

Place the door in position on the tray, fix the wall 
channels to the walls using 8 x 32mm screws 
and screw caps.

6

a: 

Check that the door is centrally positioned and perfectly vertical. Drill inside of the 

wall channels using a 3mm drill bit in the two lower positions shown. Fix using 2 x 
10mm screws and screw caps. 

b: 

Check the door is vertical, drill the next 4 holes and fix using 4 x 10mm screws  

and screw caps.

a

b

10mm

ø 3

mm

32mm

X

X = Door widths 

 -  700 Door = 650 - 700mm  

  760 Door = 710 - 760mm  

  800 Door = 750 - 800mm  

  900 Door = 850 - 900mm

Summary of Contents for OPTIMA PIVOT DOOR

Page 1: ...e sure there are no hidden pipes or cables hidden in the wall where you intend to drill Wear safety goggles shoes and appropriate clothing BEFORE INSTALLATION Check that the shower tray is level in all directions The enclosure will not sit correctly on an uneven surface If uneven the wall channels may not fit and the doors may not shut correctly The enclosure should be fitted on tiled walls which ...

Page 2: ...ay and tiles resulting in damp patches on the wall and under the tray 1 a b CUSTOMER CARELINE 01746 713410 8 PN3230 8 PN3225 6 14 1 1 PN3222 700 PN40222 760 PN40223 800 PN40224 900 PN40225 PN80519 PN10801 PN10801 PN4748 32mm 10mm Check contents of pack before installation If anything is missing contact our Customer Careline for assistance Fit the door handles to the door ensuring the supplied hand...

Page 3: ...the door ø 6 5 mm 4 a b c 3mm min 10mm ø 3 mm 5 Place the door in position on the tray fix the wall channels to the walls using 8 x 32mm screws and screw caps 6 a Check that the door is centrally positioned and perfectly vertical Drill inside of the wall channels using a 3mm drill bit in the two lower positions shown Fix using 2 x 10mm screws and screw caps b Check the door is vertical drill the n...

Page 4: ...ene parts of this packaging can be recycled End of life This product contains materials such as aluminium and glass which can be recycled Please contact your local authority to find your nearest recycling centre IMPORTANT You must not use the shower for 24 hours after installation of the enclosure DO NOT use bleach scouring powders solvents or other aggressive cleaning agents To clean use warm soa...

Reviews: