24
Problem
The appliance does not
cool sufficiently
The appliance cools too
hard
The appliance does not
cool at all
The appliance is noisy
Possible cause
The thickness of the frost is greater than 5 mm on
the cooling plate.
Thermostatic control is set too low.
Too many foods to be cooled were put in.
Very warm foods were put in.
Door is not shut properly.
The drip tray is in the closed position.
There is no inside cool air circulation.
The thermostatic control is set too high.
The drip tray is in the opened position.
Plug is not connected to the mains socket proper-
ly.
There is no voltage in the mains socket.
Thermostatic control is in 0 position.
The appliance is not supported properly.
Solution
Defrost the appliance.
Set higher position.
Put fewer foods to be cooled.
Put foods max. at room temperature.
Check if the door is shut.
Set the opened position.
Provide inside cool air circulation.
Set lower position.
Set the closed position.
Check if the connection is proper.
Check if there is voltage.
Check setting of thermostatic control.
Check if the appliance stands stable (all the four
feet should be on the floor).
Inasmuch as the advice does not lead to result, call the nearest brand-mark service.
GB
If something does not work
During operation of the appliance some smaller but
annoying trouble can often occur, which does not
require calling a technician out. In the following chart
information is given about them to avoid unnecessary
charges on service.
We draw your attention that operation of appliance goes
with certain sounds (compressor- and circulating
sound). This is not trouble, but means normal opera-
tion.
We draw it to your attention again that the appliance
operates discontinuously, so the stopping of com-
pressor does not mean being no-current. That is
why you must not touch the electrical parts of the