User can change parameters from remote controller.
Press START to change parameters
Press FUN to get each parameter mode
and save value
Press NEXT to move next mode
Press UP to get higher value setting
Press DOWN to get lower value setting
Type-in user want parameters from 0 to 9
Once all change parameters done, press
END to exit from program mode
G.
Output Monitoring Setting
Connect RJ-45 cable from ionizer unit to process tool
alarm port or Model 521 alarm multiport.
8.
Maintenance
The performance of the ionizer is designed to be maintained
primarily by the internal circuitry. Occasional cleaning of the case and
emitter points is the only routine maintenance required. When user
perform cleaning emitter points, CPM test required to make sure
output of ionizers are fine.
START
FUN
NEXT
UP
DOWN
0 ~ 9
END