P16.XY20 Piezo Nanopositioning Scanner User Manual
6
4. Operating environment
A clean, dustfree and non-corrosive environment
Operating temperature : -20~80℃
Relative humidity : <60%
Recommended voltage range is 0~120V for long-term use and lifetime
FIG.2 P16.XY20 Installation diagram
5. Installation and operation
Safety check should be carried out before installation, such as whether the connection wire
is damaged or broken, whether the drive power supply is grounded, etc.
5.1 Installation and Precautions
Installation diagram of P16.XY20 is as follows:
1.Ensure that the installation plane is relatively flat.
2.Use M3 screws to mount P16.XY20 on the mounting surface directly and tighten it.
3.Grounding protection for connection, as shown below.
M3 hole for load mounting
M2.5 hole for grounding
Motion surface
M3 hole for mounting