EM 9250
Operator’s manual
107
UK
weight Pe must be within an angle of 120°, as shown in Fig. 20.
20
Figure 20. Conditions necessary for using the Hidden weights programme
To use this programme, proceed as follows:
1 Turn the wheel until the central element of the corresponding position indicator lights
up.
It is recommended to keep the wheel in position using the pedal brake.
2 Press the
key to activate the programme.
Programme activation is indicated by the illumination of the LED
on the display
panel.
3 If the weight-holder device is present, turn the wheel again until the central element
of the outer side (Pe) position indicator lights up.
4 Turn the wheel to the point where the first outer weight (P1) should be applied behind
a spoke. The machine will display the following message:
To select the exact position of the weight P1 relative to the Pe unbalance, use 6 o'clock
as the reference if the “LAS” configuration is active and 12 o'clock if the “H12” or “CLP”
configuration is active.
The angle between P1 and Pe must be less than 120°.
5 Press the
key to memorise the first spoke.
6 Turn the wheel to the point where the second outer weight (P2) should be applied
behind a spoke. The machine will display the following message: