76
EM 9250
Operator’s manual
IMPORTANT:
for the correct and safe operation of the machine, the lighting level in the
place of use should be at least 300 lux.
The floor must be strong enough to support a load equal to the weight of the equipment
plus the maximum load allowed. The support base on the floor and the envisaged fixing
means must also be taken into account.
Environmental operating conditions must comply with the following requirements:
- relative humidity ranging from 30% to 80% (without condensation);
- temperature ranging from 0° to +50°C.
WARNING
For information concerning the technical features, warnings and maintenance instruc-
tions consult the related operator manuals provided with the documentation of the
machine.
CAUTION
The machine must not be operated in potentially explosive atmospheres.
The machine is supplied partially disassembled and is to be assembled according to
the procedures described below.
Installing the wheel guard with the corresponding mounting (Fig. 4)
- Install the bush (A, fig. 4) on the pivot (B, fig. 4). While doing this, ensure that the groove
on the pivot is aligned with the pin in the bush.
- Fasten the tube on the pivot using the M12 screw supplied.
- Insert the metal tube (D, Fig. 4a) into the two plastic guard front holes (C, Fig. 4a).
- Couple the guard to the rear side of the tube by inserting it into the correct position
with snap-in coupling (E, Fig. 4a).
- Secure the wheel guard by tightening the screw provided (F, Fig. 4a).
4
4a