3
-
at the end of the wheel spin, if the calibration has run successfully the message "END
CAL" will be displayed; otherwise, the message "Er3 CAL" will appear for a short time;
-
press F to exit the calibration function.
NOTES
-
On completion of the calibration procedure, remove the calibration weight and remove
the automatic calibration disc from the balancing machine;
-
the user can interrupt the program at any moment by pressing F;
-
if the machine displays "ER3 GE2", this indicates an error in performing the calibration
procedure; repeat the calibration;
-
message "d 212" displays if the inside sensor has failed; to continue with calibration,
place the inside sensor against the blue hole on the calibration disc and enter the distance
value read on the sensor ruler in manual mode.
-
the calibration procedure described above is valid for any type of wheel!
90 Automatic position search (RPA):
Selecting the program results in the machine displaying:
-
message RPA on the LH display;
-
message ON or OFF on the RH display.
When this program is selected it is possible to enable automatic weight position search by
pressing Enter.
Select:
-
OFF
to disable automatic position search;
-
ON
to enable automatic position search;
To exit from the program (and the service environment) press F.
91 Cancel/reset:
-
display of the first gram of unbalance;
-
rounding to the nearest inch of the diameter and width measured with the automatic
sensors.
Selecting the program results in the machine displaying:
-
message "1 oF" on the RH display;
-
message "on .5" on the LH display.
In normal operation, even when unbalance display in "gr x 1" is selected, the first gram of
unbalance is not displayed. In this condition, when program "91" is selected the machine
displays "1 oF" on the RH display. Pressing Enter enables display of the first gram and
amplification of the machine's sensitivity (the RH display reads "1 on"). When Enter is
pressed again, the system switches from one mode to the other in alternation.
At switch-on the machine presets to display the diameter and width measured with the
automatic sensors rounded to the nearest inch. In this condition, when program "91" is
selected the machine displays "on .5" on the LH display. Pressing Enter enables displaying
the diameter and width measured with the automatic sensors with a precision of a tenth of an
inch (the LH display reads "oF .5"). Press Enter again to switch between the two modes.
Important
Press Enter to change the display setting when the central element of the position centered indicator
is on. Press either of the two arrow keys to transfer control from one display to the other.
To exit from the program (and the service environment) press F.