Technical Support Manual – 05/2015 Rel. 0
Page 5
If both pick-up signals differ from, but are similar to the values indicated in table T9.2 check if:
•
The dimensions of the wheel are different from those of the reference wheel;
•
The wheel is not balanced;
•
The 50 grams of the imbalance weight are placed on the inner side;
•
The imbalance weight does not exceed or drop below 50 grams;
•
The regulation spring pre-charge is correct;
•
Both pick-ups are original;
•
The CPU-C1 runs properly (check this by running the VFC TEST described below).
If both pick-up signals differ considerably from the values indicated in annex 1 and from each other, check if:
•
The cables of pick-ups A and B have been connected to the wrong connectors;
•
The pick-up regulation spring pre-charge is correct;
•
The CPU-C1 runs properly (check this by running the VFC TEST described below).
If only one pick-up signal differs considerably from the values indicated in table T9.2, check if:
•
I The cables of pick-ups A and B have been connected to the wrong connectors;
•
The pick-up regulation spring pre-charge is correct;
•
Both pick-ups are original;
•
The CPU-C1 runs properly (check this by running the VFC TEST described below).
To exit the pick-up signals test, press [F+P9]
.
dPy
Display Test
This menu option allows you to run the 7-segment display and LED test. Once you have accessed this menu option, you can switch
the 7 different configurations of segments and LED units on and off to check their proper operation. A special configuration switches
all the 7 display segments and LED units on (see figures F2.8 and F2.9).
Figure F2.8: Display Test Message
Figure F2.9: Display value message
Browse the configurations available with keys [P4]
or [P5]
.
Replace the CPU-C1 if one or more segments fail to switch on. This is also valid for the LEDs.
To exit the Display Test program, press [F+P9]
.
Summary of Contents for MEC 1
Page 1: ...EQUILIBRATRICI MEC 1 MEC 1 BAT TECHNICAL SUPPORT MANUAL UK...
Page 2: ......