Use and Maintenance Manual – 09/2016 Rel. 0
Page 28
18. UTILITY PROGRAMS
Utility programs are available only in NORMAL mode.
18.1 Selecting the imbalance display resolution
The machine has two wheel imbalance display resolutions. The two resolutions are defined as X1 (high resolution) and X5 (low
resolution). The resolution with which the imbalances of the wheel are displayed varies depending on the weight unit of
measurement as indicated in table T18.1.
Table T18.1: Display resolution
Set resolution
Imbalance unit of
measurement
Display resolution
Notes
X1
(High resolution)
Grams
1 gram
Ounces
0.1 ounces
X5
(Low resolution)
Grams
5 grams
The X5 resolution is set by default at start-up
Ounces
0.25 ounces
To view the X1 resolution imbalance (high resolution), press [F+P1]
. The machine will display the message
visible in figure F18.1 for one second and the LED next to the button lights up. Imbalance values are now displayed in X1 resolution
(high resolution).
Figure F18.1: Enabling imbalance display in high resolution
To return to viewing in X5 resolution (low resolution), press [F+P1]
. The machine will display the message
visible in figure F18.2 for one second and the LED next to the button will turn off. Imbalance values are now displayed in X5 resolution
(low resolution).
Figure F18.2: Disabling imbalance display in high resolution
18.2 Selection of the static imbalance display
To view the static imbalance, press [F+P2]
. The machine will show the static imbalance value on the display
as seen in figure F18.3 and the LED next to the button lights up.
Figure F18.3: Static imbalance display enabled. The right display indicates the entity of the static imbalance
To return to dynamic imbalance display, press [F+P2]
. The LED next to the button will turn off.