Use and Maintenance Manual – 08/2018 Rel. 4
Page 16
14.1 Temporary disabling of the diameter and distance sensor
If the machine displays the error code
ERR 064
(Distance/Diameter sensor not in the rest position) at switching on, although being in
rest position or
ERR 066
(The Diameter sensor is enabled but disconnected) it means that an anomaly occurred in the acquisition
system. However, it is possible to temporarily disable the acquisition system by pressing on icon
. The disabling condition
is highlighted by the
status icon, indicating that the automatic acquisition system is disabled and that the machine is ready
for use. As it is not possible to use the automatic acquisition system, the wheel dimensions must be entered manually. By turning the
machine off and back on again, the error code will re-appear and you will once again need to proceed as described above. If the
automatic acquisition system is malfunctioning and it blocks the machine in a permanent acquisition function, the temporary
disabling could be done also after the machine is switched on.
Note: the temporary disabling of the Distance/Diameter sensor also acts on the sensor for the automatic acquisition of width.
If using the Distance / Diameter sensor, we realize that it does not work, you can disable the sensors by proceeding as described
below:
Ph.
1
Press on icon.
2
The disabling condition is
highlighted by the status icon.