Use and Maintenance Manual – 08/2018 Rel. 4
Page 17
3
If the wheel balancer
switches off, when
switch on the gauges
activate again.
14.2 Temporary disabling of the width external sensor
If the machine displays error code
ERR 065
(Width sensor not in the rest position) when powered up, even if in rest position or
ERR
067
(The Width sensor is enabled but disconnected) it means that an anomaly occurred in the acquisition system. However, it is
possible to temporarily disable the width sensor by pressing on icon
. The disabling condition is highlighted by the
status icon, indicating that the automatic acquisition system is disabled and that the machine is ready for use. As it is not possible to
use the automatic acquisition system, the wheel dimensions must be entered manually. By turning the machine off and back on
again, the error code will re-appear and you will once again need to proceed as described above. If the automatic acquisition system
is malfunctioning and it blocks the machine in a permanent acquisition function, the temporary disabling could be done also after
the machine is switched on.
Note: the temporary disabling of the Distance/Diameter sensor also acts on the sensor for the automatic acquisition of width.
15. MACHINE CALIBRATION
To function properly, the machine must be calibrated. Calibration allows storing the mechanical and electrical parameters specific to
each machine so as to provide the best balancing results.
15.1 When to carry out machine calibration
Table T15.1 lists the cases in which machine calibration should be carried out.
Table T15.1: Conditions for carrying out machine calibration
Condition
Status
Who must perform it
When the machine is installed at the final user.
Mandatory
Technical Service
When the electronic circuit board is replaced.
Mandatory
Technical Service
When a mechanical part linked to the pick-up signals (pick-up, pick-up compression
springs, suspension unit + shaft) is replaced.
Mandatory
Technical Service
When the pick-up compression springs adjustment are modified.
Mandatory
Technical Service
When the encoder disc is replaced.
Mandatory
Technical Service
When a different motorbike adaptor is used since the last calibration for MOTO
Wheel Type.
Mandatory
Final user and/or
Technical Service
When the machine doesn’t show accurate results for balancing.
Recommended
Final user and/or
Technical Service
When there are wide and constant variations due to environmental humidity and
temperature (for example seasonal changes).
Recommended
Final user and/or
Technical Service