INSTALLATION INSTRUCTIONS
1. Locate the dispenser indoors on a level counter top.
A.
LEG OPTION
Unpack the four (4) legs and install them into the threaded holes provided in the bottom of the unit.
The installer must provide flexibility in the product and utility supply to permit shifting the position of the
dispenser sufficiently to clean the area beneath it.
NOTE:
Before installing legs, the plastic plugs must be removed. Remove by pushing the center in
and
then removing the plugs.
B.
COUNTER MOUNTING
The ice dispenser must be sealed to the counter. The MOUNTING TEMPLATE (See Figure 3) draw-
ing indicates where openings can be cut in the counter. Locate the desired position for the dispenser,
then mark the outline dimensions on the counter using the template drawings. Cut openings in
counter.
Apply a continuous bead of National Sanitation Foundation (NSF) listed silastic sealant (Dow 732 or
equal) approximately 1/4
?
inside of the unit outline dimensions and around all openings. Then, position
the unit on the counter within the outline dimensions. All excess sealant must be wiped away immedi-
ately.
2. Utilities routing may be made through the rear of the cabinet by removing the plastic rear panel by the inlet
of the cold plate and removing the kock-out for the drain hose.
Optional routing through the bottom of the cabinet:
A.
Tip unit to the side to access the drain block located behind the drip tray.
B.
Replace the straight fitting with the 90
°
fitting that is in the drain kit supplied with the unit.
3. Beverage System: Connect the beverage system product lines as indicated in Figure 4. This work should
be done by a qualified service person. Note that the hoses are marked with numbers (1 through 6) for syrup
connections and “CW”for carbonated water connections. The plain water is marked “W”.
4. Clean the hopper interior (see CLEANING INSTRUCTIONS on page 7).
5. Connect the power cord to a 120 volt, 60 cycle, 3-wire grounded receptacle.
6. If the legs are not used, the dispenser must be sealed to the counter with RTV.
NOTE: Water pipe connections and fixtures directly connected to a potable water supply shall be sized,