Energize6 Service Manual
Publication Number: 621058457SER
- 36 -
© 2012, IMI Cornelius Inc.
Figure 41.
R
EPLACING
THE
M
ESH
S
TRAINER
There is a mesh strainer in each of the output lines from the carbonated water
pumps. Occasionally, one of these strainers may become clogged and require
replacement. To replace the mesh strainer, perform the procedure in Table 28.
6
Replace the head master, shown in Figure 41.
7
Replace the filter/dryer, shown in Figure 37 on page 33.
8
Evacuate the system.
9
Restore the proper refrigerant charge (shown on the unit nameplate) to the
system and verify proper system operation.
10
Replace the access panel.
Table 27.
Step
Action
Head
Master
Compressor
Table 28.
Step
Action
1
Turn off the electrical supply to the unit.
2
Turn off the water supply to the unit.
3
Remove the cover using the procedure in “Removing the Unit Cover” on page 14
4
Drain the system pressure by opening a dispense valve.
5
Vent the carbonators by opening the relief valves, shown in Figure 10 on page 9.
6
Turn off the recirculation shutoffs, shown in Figure 22 on page 24.
7
Remove the high pressure plumbing connector from the pump, shown in
Figure 23 on page 24.
8
Remove the mesh strainer from the check valve, shown in Figure 42.
9
Install a new mesh strainer, using teflon tape to insure a proper seal.
10
Check and replace the gasket inside the fitting, shown in Figure 14 on
page 20, before reconnecting the outlet plumbing.
11
Reconnect the outlet plumbing to the pump, using teflon tape to insure a
proper seal.
12
Replace the overflow tube, being careful to lubricate the O-rings on the bot-
tom of the tube with water before inserting it into the drain.
Summary of Contents for Energize6
Page 47: ...Energize6 Service Manual 2012 IMI Cornelius Inc 43 Publication Number 621058457SER ...
Page 48: ...Energize6 Service Manual Publication Number 621058457SER 44 2012 IMI Cornelius Inc ...
Page 50: ...Energize6 Service Manual Publication Number 621058457SER 46 2012 IMI Cornelius Inc ...