IDC Pro 255 Service Manual
© 2016, Cornelius Inc.
- 7 -
Publication Number: 621058649SER
E-B
OX
C
ONFIGURATION
!
WARNING:
Disconnect power to the unit before accessing the E-box.
Figure 3.
1.
Left hand valve bank MFV board.
2.
Right hand valve bank MFV board.
3.
12VDC/24VDC Power Supply.
A. 12VDV – Control voltage for MFV boards and computer.
B. 24VDC – Powers display and touchscreen.
4.
30VDC Power supply for LH Valve Bank.
5.
30VDC Power supply for RH Valve Bank.
6.
Circuit Breakers as follows:
A. 5A – 12VDC
B. 4A – 24VDC
C. 3A – 30VDC
D. 3A – 30VDC
7.
Agitation Timer / Liquid Level Control Board.