IDC Pro 255 Operator Manual
Publication Number: 621058649OPR
- 16 -
© 2016, Cornelius Inc.
Q
UARTERLY
C
LEANING
AND
M
AINTENANCE
Perform the daily, weekly and monthly cleaning procedures in addition to the quarterly cleaning procedures in the fol-
lowing sections.
The quarterly procedures are:
• Daily Cleaning and Maintenance
• Weekly Cleaning and Maintenance
• Monthly Cleaning and Maintenance
• Cleaning and Sanitizing the Cold Plate
Cleaning and Sanitizing the Cold Plate
To clean the cold plate, perform the procedure as shown in Table 7.
5
Using a mechanical spray bottle
filled with sanitizing solution, spray
the entire interior and the agitator
assembly. Allow them to air dry.
Figure 20.
6
Replace the hopper cover or close the manual fill door on the ice maker (if equipped).
Table 7.
Step
Action
1
Remove power from the unit.
2
Open the unit display.
3
Remove the splash panel and the
cold plate covers to expose the
bottom of the cold plate.
Figure 21
MOUNTING SCREW