1LAN-SDAN-8293
Software Defined
Access Node
Quick Installation Guide
QUICK INSTALLATION SHEET I SDLAN-000-8293 I APRIL 2018 I
Page 5
4 USING SURFACE MOUNT
CRADLE (1LAN-SDAN-SMCRD) |
Notes: Fiber can be terminated using:
A. Unicam® Connectors
B. Fuselite® Connectors
C. Fusion Spliced Pigtail
METHOD A. Unicam® SC/APC Connector |
Step 1
Terminate fiber using Corning Unicam® standard
recommended procedure
(
https://www.corning.com/catalog/coc/documents/standar
d-recommended-procedures/006-369.pdf
Figure 8 ONT Fiber Port
Step 2
Remove port cover.
Step 3
Plug SC/APC connector into fiber port on ONT (Figure 8).
Step 4
Replace port cover making sure fiber is not pinched or
damaged.
METHOD B. Fuselite® SC/APC Connector |
Step 1
Terminate fiber using Corning Fuselite® standard
recommended procedure
(
https://www.corning.com/catalog/coc/documents/standar
d-recommended-procedures/LAN-1468-AEN.pdf
Step 2
Remove port cover.
Step 3
Plug SC/APC connector into fiber port on ONT Figure 8).
Step 4
Replace port cover making sure fiber is not pinched or
damaged.