5.

Components

5.1

Components are illustrated in Figure 2.

The base plate is the dark metal part inside
the enclosure to which the components are
attached. It is secured by one screw in each
corner.

There are top and bottom mounting
brackets.

The splice tray holder is removed for
clarity.

The fan-out bracket is underneath the splice
tray mounting location.

Figure 2

5.2

An installation kit is provided that

includes cable ties, central member strain-relief
hardware, a sheath retention kit and a quick-
release latch kit.

6.

Unpacking Stubbed Units

Follow the directions in Standard
Recommended Procedure 003-310, provided
with the shipping container, to remove the
stubbed unit from its packaging.

Mounting Bracket

Ground Kit Loca-
tion
(When Required)

Radius Control Guides

Record
Label

Splice Tray
Mounting
Location

Central Mem-
ber
Strain-Relief
Bracket

Connector
Panel
Bracket

Sheath
Retention
Bracket

Drop Cable
Strain-Relief
Bracket

Splice Tray Holder

Summary of Contents for EDC-06P-NH

Page 1: ...mounted and how the distribution cable and drop cable will be routed to the unit 2 Description 2 1 The EDC that stores and protects fiber optic connections and splices in an outdoor environment The ca...

Page 2: ...pieces of fiber stick to your clothing or drop in the work area where they can cause injury later Use tweezers to pick up cut or broken pieces of the glass fibers and place them on a loop of tape kept...

Page 3: ...igure 2 5 2 An installation kit is provided that includes cable ties central member strain relief hardware a sheath retention kit and a quick release latch kit 6 Unpacking Stubbed Units Follow the dir...

Page 4: ...Figure 4 Figure 5 b Drive 1 4 inch screws or wall anchors through the stabilizer bracket and into the mounting surface Do not install a screw in the bottom hole of the stabilizer bracket at this time...

Page 5: ...tside of the armor and sheath Tap the sheath above the ground clamp base to set the teeth Stop Base Plate Position the top plate and lock nut on the outer sheath over the base plate Tighten with a 10...

Page 6: ...ed washer f Arrange the buffer tubes to ensure clearance around the central member clamp assembly and hardware g Tighten the hex nut h Install the two flat washers i Loosely install the other hex nut...

Page 7: ...irect connectorization per manufacturer s instructions If installing BTF kits proceed to section 12 Figure 12 Figure 13 Figure 14 Splice Tray Holder Splice Tray Holder Bracket NOTE Pigtails are fiber...

Page 8: ...els into the connector support bracket Figure 16 10 6 Repeat for all required panels Figure 15 11 Splicing 11 1 The unterminated ends of pigtails are spliced to buffered fibers in a splice tray Figure...

Page 9: ...he cable tie too tightly 11 4 Splice fibers as described in instructions for the splicing method you are using 11 5 As you complete a splice label the connector end of the pigtail with its port identi...

Page 10: ...es and each successive loop should be in the section above the previous loop d At the third loop reinstall the splice tray holder and trays Figure 21 NOTE Cable ties can be loosely attached to organiz...

Page 11: ...o avoid damaging the connectors during installation 12 7 Label the connector end of the pigtail with its port identifier Record information appropriately on the record label inside the front door Figu...

Page 12: ...r Figure 27 d Tighten the hex nut e If the central member is metallic place the eye of a ground wire 6 AWG purchased separately in appropriate length from any electrical supply store under the U shape...

Page 13: ...fications The unit weighs 6 9 kg 15 2 lb 21 cm 8 3 in 37 cm 14 5 in 42 cm 16 5 in Corning Cable Systems reserves the right to improve enhance and modify the features and specifications of Corning Cabl...