STANDARD RECOMMENDED PROCEDURE 003-139-AEN | ISSUE 1 | JANUARy 2017 | PAGE 5 OF 13
Step 6:
Clean and install an LC to LC
jumper- Reference Jumper
no. 2 (
RJ2
) into
M1
and the LC
adapter (Figure 7).
Figure 7
Step 7:
Verify that the
RJ1/ RJ2
mated pair are acceptable with a loss ≤0.10 dB for
multimode and ≤0.20 dB for single-mode.
Step 8:
Disconnect
RJ2’s
LC connector from the LC adapter and protect it with a clean dust
cap until you are ready to start the system testing.
Step 9:
Clean and install an LC to LC
jumper-Reference Jumper
no.3 (
RJ3
) into
M2
and the LC
adapter (Figure 8).
Figure 8
Step 10:
Verify that the
RJ1/RJ3
mated pair are acceptable with a loss ≤0.10 dB for
multimode and ≤0.20 dB for single-mode.
Step 11:
Disconnect
RJ1’s
LC connector from the LC adapter and protect it with a clean dust
cap.
Step 12:
Leave the LC adapter on the end of
RJ3
for the remainder of this procedure since it
will be required for mating to the TAP port test harness.
7.3
Referencing is now complete.
IMPORTANT:
From this step on, do NOT disconnect the connectors on either the Light Source or
meter port adapters.
Do NOT
disconnect
Do NOT
disconnect
HPA-0759
LC
adapter
0.15 dB
multimode only
RJ1
Reference
Jumper no. 2
RJ2
M1
Light
Source
Do NOT
disconnect
Light Source
M1
HPA-0760
LC
adapter
Dust cap
RJ2
Do NOT
disconnect
0.3 dB
multimode only
RJ 1
RJ3
M2
0.15 dB