STANDARD RECOMMENDED PROCEDURE 003-139-AEN | ISSUE 1 | JANUARy 2017 | PAGE 7 OF 13
8.3.
Table 2 provides a complete guide to the test sequence with a light source at the MTP Tap
module “A” (“Near end”) and a meter at Module “B”, or the “Far end” of the system shown in Figure 10.
Source LC Position at “A”
Meter at Module “B” LC Position
A-2
B-1
A-4
B-3
A-6
B-5
A-8
B-7
Table 2:
Test Sequence
8.4
To begin testing the Live Portion of the MTP Tap module (Figure 10):
Step 1:
Install the
Light Source/RJ1
LC connector adapter
on the LC number 2 of a test
harness plugged into the front-mounted LIVE Port of the MTP Tap module.
Step 2:
Install
RJ2’s LC connector
into the number 1 port of the EDGE8 module (Module
“B” in Figure 10
).
Figure 10
Light
Source
Test harness
M1
RJ1 and adapter
Do NOT
disconnect
Do NOT
disconnect
0.00 dB
EDGE8 Module “B”
B
2
3
B
1
2
1
A
HPA-0999-EDGE8
multimode only
“Near end”
“Far end”
EDGE8 MTP Tap Module “A”
Note: Fiber loss
depends on length
of system
LC #1
LC #8
LC #2
“A”