2.5
Head End Unit (HEU) Installation
The HEU chassis is supplied empty and only includes the factory assembled Fan Module (FAM) + additional
modules according to the ordered PN. All other modules are ordered separately and must be installed.
NOTE: If DCM cards are available, ensure they are installed in the IHU only (not in the HEU)!
➢
Interfaces
The following figure shows the internal positions of HEU
Figure 9: HEU Slots and Interfaces
Each HEU includes 14 slots supporting the following modules:
•
RIX slot (Slot 1)
•
RIM slots (Slots 2-7)
•
One OIX slot (Slot 14)
HEU supports the following expansion connection options: To a single 7 IHUs
➢
Example of system connection
The following figure described the optimal rack installations for a maximum 4x4 HEU-IHU configuration in
shared and dedicated equipment scenarios
RIM Slots 1-12
RIX
PSM
HCM/ACM
RIX