User Manual v1.0
Corning Restricted and Confidential Proprietary - Controlled content
UM - Everon 6000 DAS - 19-DEC-2020.docx| December 2020
|Page 69 of 170
2.5.3
Install the Modules in the Chassis
Note: For modules with ejectors (i.e. RIM, RIX and HCM/ACM)
–
verify that the ejectors are
completely open when inserting in dedicated slot and then push in until the module clicks in to
the backplane. See Figure 11: Module Captive Screws and Ejectors below, showing an example of
module type captive screws and ejectors.
Refer to the Figure 9: HEU Slots and Interfaces for module locations. Remove blank panel and slide in the
relevant module (chassis slots are 100% mistake proof):
•
(One) HCM (for Standalone/Master HEU units) / (One) ACM (for Auxiliary HEU unit)
•
(One to two) PSM
–
for single power supply installations, install the PSM in either (PSM) slot
•
(Two) RIX modules
•
(One to 12) RIM
–
no need to terminate unoccupied RIM slot
Referring to the following figure, secure the modules to the backplane by:
•
Closing the ejectors (for relevant modules)
•
Tightening the captive screws
Figure 11: Module Captive Screws and Ejectors