Quick Installation Sheet | CMA-481-AEN | Page 7
Corning Optical Communications
7.
RF CONNECTIONS TO HX WCS
Step 1.
Perform the WCS service connections as follows:
Connect from…
To…
HX 2.5 GHz TDD “WCS RU” mini
DIN 4.3-10 type
duplexed port
HX WCS “ANT” mini DIN 4.3-10
type duplexed port
Notes:
• For SISO installations, the connections are from
HX 2.5 GHz TDD ANT 1 (MUX) “WCS RU” port to
the HX WCS ANT 1 (MUX) “ANT” port.
• For MIMO installations, the MIMO 2 Stream
connections are performed between the
HX 2.5 GHz TDD ANT 2 (MUX) “WCS RU” port
and the HX WCS ANT 2 (MUX) “ANT” port.
Step 2.
Connect broadband antenna coax to HX-2.5 GHz
TDD MUX module “ANT” port of (two for MIMO
models) and to broadband DAS antennas. See
Figure 12.
ATTENTION!
Terminate any unused RF ports with a
50 Ohm termination load.
Figure 12. HX 2.5 GHz TDD SISO/MIMO
RF Connections to HX WCS and Antenna
Connections