Preface Material
MA1000 Installation and Configuration Guide
21
4.2.5
RIU Connections
Refer to the RIU Products Installation and Configuration Guide for detailed instructions on
connecting the RIU model in your installation.
4.2.6
BU Connections
NOTE: It is assumed that the patch panel cabinet (SC/APC adaptors) for fiber optic cable
connections is installed in the rack near the BUs.
1. Connect (3/125/900) pigtail with SC/APC connectors between splice tray and patch panel
cabinet.
2. Connect (3/125/3000) SC/APC jumpers between the corresponding BU and patch panel.
3. Connect the fiber optic cables from the BU to the RHUs through the patch panel cabinet.
4. Connect the UL RF Output and DL RF Input connectors to the RIU or UL and DL connectors
or to the passive interface (such as Interface Box) in topologies that do not include RIUs.
4.2.7
Controller Connections
Refer to the
NMS 410/430 or SC-450 Installation and Configuration Guide
for connections.