background image

Installation Manual | CMA-794-AEN | Page 20

MOUNT THE EU-O ON THE WALL 

Attach Handle to EU-O 

Attach the 19-inch mounting brackets to the rear of the EU-O, using 4 screws M3×16 per bracket 
and the Phillips screwdriver. Observe the orientation of the brackets. 

Figure 30.

  Attaching a 19-in Mounting Bracket 

Mount EU-O to Wall 

Figure 31.

 Marking the Position of Mounting Holes 

1. Hold the EU-O to the installation

location and mark the position of
the 4 mounting holes in the
mounting brackets; see arrows in
Figure 18.

2. Drill the mounting holes according

to the chosen mounting
accessories.

Figure 32.

 Mounting Completed 

1. Attach the dowels, expansion

screws, and fasten the EU-O to
the wall.

Summary of Contents for Nano Power E62-N2RU

Page 1: ... over his or her exposure by leaving the area or by some other appropriate means Awareness of the potential for RF exposure in a workplace or similar environment can be provided through specific training as part of a RF safety program GENERAL INFORMATION The E62 N2RU is a low power remote unit supporting cellular technologies on fiber optic cable using the CPRI protocol The N2 is ideal for multiop...

Page 2: ...ansceiver 9 INSTALLATION OF THE A2 10 MOUNT THE A2 IN THE RACK 10 A2 Accessories 10 Attach A2 Handle 11 Attach Sliding Rails and A2 to Rack 11 Fan Installation 12 Connect Power and Ground Cable to A2 13 MOUNT THE A2 ON THE WALL 14 Attach Handle to A2 14 Mount A2 to Wall 14 Connect Power and Ground Cable to A2 15 A2 MOUNTING DIMENSION SPACING 16 INSTALLATION OF THE EU O 17 MOUNT THE EU O IN THE RAC...

Page 3: ... II 25 Buckle Up and Connect Wire 26 To Perform Maintenance on the E62 N2RU 27 E62 N2RU CEILING INSTALLATION WITHOUT SUSPENDED CEILING 28 Draw Circles for Plastic Expansion Nails 28 Assemble Mounting Bracket 29 Buckle Up and Connect Wire 29 To Perform Maintenance on the E62 N2RU 31 DUAL E62 N2RU CEILING INSTALLATION WITH THE SUSPENDED CEILING 32 Dual E62 N2RU Accessories 33 Assemble Bracket I III ...

Page 4: ... avoid any damage to PCB PSU etc Keep equipment powered off during installing or modifying Low path loss cables connected to antennas are highly recommended SITE CONSIDERATIONS Everon 6200 complies with FCC RF exposure limits for an uncontrolled environment The system delay should be taken into consideration when there are neighboring BTS sites with overlapping coverage Pick an ideal easy to reach...

Page 5: ...ladder and other tools are needed for E62 N2RU installation which is not currently offered from Corning Customers are to provide these tools themselves SYSTEM CABLING Here are the key features of Everon 6200 E62 N2RU system cabling Master A2 connects EU O using single port bidirectional SFP module EU O connects E62 N2RU using dual ports SFP module See Section Optical Transceiver Module for SFP mod...

Page 6: ...U P I Vin 142 92W Power required from PSU Vin 56 V Voltage of E62 N2 PSU Rw Vin Vout I 6 90 Rw resistance of the wire Vout 48 1 20 38 4 V Minimum input voltage of E62 N2RU Rw Rd D D distance of the wire total length of supply return cable Rd resistance per meter of the wire I Pn Vout 2 552A I Injected current Cable type Voltage Drop D Rw Rd meters Max Fiber Distance meters ohms meter 2x distance b...

Page 7: ...for class 2 installation Rw Pw Iw2 6 8992 Rw resistance of the wire Vin 56 V Voltage of N2 PSU Rw Rd D D distance of the wire total length of supply return cable Rd resistance per meter of the wire Iin Pin Vin 1 786 Iin Max injected current to not exceed 100 W Cable type Voltage Drop D Rw Rd meters Max Fiber Distance meters ohms meter 2x distance between PSU and N2RU there and back Distance betwee...

Page 8: ...ction the transceivers of two sides must be paired the wavelength of one side is 1271 nm and the wavelength of another side is 1331 nm Otherwise it will fail the connection All lower level devices under this port won t be working in the system All the optical ports of all type devices have triangle LED indicators pointing to each port which represent the synchronization status of the upper and low...

Page 9: ...er and optical receiver should correspond to each other In other words the optical transmitter of optical module A should correspond to the optical receiver of optical module B and the receiver of A should correspond to the transmitter of B The optical receiver and transmitter terminals of the optical module can be determined by the triangular mark on the optical module The triangular mark in the ...

Page 10: ...Installation Manual CMA 794 AEN Page 10 INSTALLATION OF THE A2 MOUNT THE A2 IN THE RACK A2 Accessories Figure 5 A2 Accessories Note The ground wire of A2 is 12 AWG and 2 meter in Accessories package ...

Page 11: ...t and the Phillips screwdriver Observe the orientation of the brackets Attach Sliding Rails and A2 to Rack Figure 7 Attached Sliding Rails 1 Attach the sliding rails Ⓑ to the rack Note The sliding rails are not included in the delivery Figure 8 Place A2 in Rack 2 Place the A2 in the rack Figure 9 Fix A2 with Screws 3 Secure the A2 using 2 screws M6 16 on both sides and the Phillips screwdriver ...

Page 12: ...n tray in the middle of 2 adjacent A2 units for cooling Note It will reduce service life if A2 unit is continuously working in a high temperature environment Fan Installation Figure 11 Fix Fan with Screws 1 Secure the fan using 2 screws M6 16 on both sides and the Phillips screwdriver Figure 12 Plug AC Power Lead 2 Plug AC power lead ...

Page 13: ...sis Figure 14 DC Power Cable Note Red is for positive Blue is for negative Connect Power and Ground Cable to A2 Figure 15 Connect Power Cable at Rear Side 1 Connect and lock the power cable at the rear of the A2 Figure 16 Connect Ground Cable at Rear Side 2 Connect and screw the ground wire at the rear of the A2 ...

Page 14: ...tion of the brackets shown in Figure 17 Figure 17 Attaching a 19 in Mounting Bracket Mount A2 to Wall Figure 18 Marking the position of mounting holes 1 Hold the A2 to the installation location and mark the position of the 4 mounting holes in the mounting brackets 2 Drill the mounting holes according to the chosen mounting accessories Figure 19 Mounting completed 3 Attach the dowels expansion scre...

Page 15: ...ower and Ground Cable to A2 Figure 20 Connect power cable at the rear of the unit 1 Connect and lock the power cable at the rear of the A2 Figure 21 Connect ground cable at the rear of the unit 1 Connect and screw the ground wire at the rear of the A2 ...

Page 16: ...Installation Manual CMA 794 AEN Page 16 A2 MOUNTING DIMENSION SPACING ...

Page 17: ...ling the EU O is virtually the same as installing the A2 Please refer to the steps described in the A2 installation for the EU O MOUNT THE EU O IN THE RACK EU O Accessories Figure 22 EU O Accessories Note The ground wire of EU O is 12 AWG and 2 meter in Accessories package ...

Page 18: ...d the Phillips screwdriver Observe the orientation of the brackets Attach Sliding Rails and EU O to Rack Figure 24 Attached Sliding Rails 1 Attach the sliding rails Ⓑ to the rack Note The sliding rails are not included in the delivery Figure 25 Place EU O in Rack 2 Place the EU O in the rack Figure 26 Fix EU O with Screws 3 Secure the EU O using 2 screws M6 16 on both sides and the Phillips screwd...

Page 19: ...acent EU O for cooling Note It will reduce service life if EU O is continuously working in a high temperature environment Connect Power and Ground Cable to EU O Figure 28 Connect Power Cable at Rear Side 1 Connect and lock the power cable at the rear of the EU O Figure 29 Connect Ground Cable at Rear Side 2 Connect and screw the ground wire at the rear of the EU O ...

Page 20: ...of the brackets Figure 30 Attaching a 19 in Mounting Bracket Mount EU O to Wall Figure 31 Marking the Position of Mounting Holes 1 Hold the EU O to the installation location and mark the position of the 4 mounting holes in the mounting brackets see arrows in Figure 18 2 Drill the mounting holes according to the chosen mounting accessories Figure 32 Mounting Completed 1 Attach the dowels expansion ...

Page 21: ...r and Ground Cable to EU O Figure 33 Connect power cable at the rear of the unit 1 Connect and lock the power cable at the rear of the EU O Figure 34 Connect ground cable at the rear of the unit 2 Connect and screw the ground wire at the rear of the EU O ...

Page 22: ...Installation Manual CMA 794 AEN Page 22 EU O MOUNTING DIMENSION SPACING ...

Page 23: ...Installation Manual CMA 794 AEN Page 23 INSTALLATION OF THE E62 N2RU E62 N2RU CEILING INSTALLATION WITH THE SUSPENDED CEILING E62 N2RU Accessories Figure 35 E62 N2 Accessories ...

Page 24: ...ket I IV 1 Assemble Mounting Bracket I IV with 6 x M3 x 6 screws Figure 37 Attaching Cable Tie to Mounting Bracket 2 Attach Nylon Cable Tie to the Bracket I IV combination Place the Bracket Figure 38 Drilling a Hole 1 Drill a hole with a diameter of 90 mm for putting Mounting Bracket I IV ...

Page 25: ...d to the reverse of the Ceiling Tiles Figure 40 Placing Bracket 2 3 Ensure the nylon tie hangs down through the hole Assemble Bracket II Figure 41 Assemble Bracket II 1 Attach Mounting Bracket II to Mounting Bracket I using 2 x M6 x 70 screws Flat Washer M6 and Spring Washer M6 Note Paired Mounting Bracket III is already assembled into E62 N2RU in factory ...

Page 26: ...II over the hooks on Bracket II Figure 43 Wire Connection Diagram 2 Connect the power cable and fiber cable to E62 N2RU Note Connect power cable first and then power it on Do NOT connect the powered cable to the E62 N2RU in case of excessive current impulse Figure 44 Installation Completed Diagram 3 Engage the rotary hook on Bracket IV into Bracket II ...

Page 27: ...2 N2RU 4 Tighten the M3 x 3 screws To Perform Maintenance on the E62 N2RU Figure 46 Unlock Rotary Hook Diagram 1 1 Depress the hook on the front of the E62 N2RU to expose top panel of E62 N2RU for debugging and maintenance Figure 47 Unlock Rotary Hook Diagram 2 ...

Page 28: ...Drawing Circles Diagram 1 1 Using the Mounting Bracket III keyholes as guides mark the position of the 2 holes to be drilled into the ceiling Figure 49 Drilling Holes Diagram 1 2 Drill 2 holes with a diameter of 10 mm and depth of 55 mm at the positions in step 1 Figure 50 Insert Plastic Wall Plugs 3 Insert plastic wall plugs into holes by hammer ...

Page 29: ...ling Bracket III Diagram 1 Figure 52 Assembling Bracket III Diagram 2 1 Assemble Mounting Bracket III to the ceiling using ST6 3 x 50 screws Buckle Up and Connect Wire Figure 53 Connecting Bar over Hooks on Bracket II 1 Clip the bar on paired Bracket III over the hooks on Bracket II ...

Page 30: ...er cable to E62 N2RU Note Connect power cable first and then power it on Do NOT connect the powered cable to the E62 N2RU in case of excessive current impulse Figure 55 Installation Completed Diagram 3 Engage the rotary hook on Bracket IV into Bracket II Figure 56 Tighten E62 N2RU 4 Tighten the M3 x 3 screws ...

Page 31: ...e 31 To Perform Maintenance on the E62 N2RU Figure 57 Unlock Rotary Hook Diagram 1 1 Depress the hook on the front of the E62 N2RU to expose the top panel of E62 N2RU for debugging and maintenance Figure 58 Top Panel of E62 N2RU Exposed ...

Page 32: ...Installation Manual CMA 794 AEN Page 32 DUAL E62 N2RU CEILING INSTALLATION WITH THE SUSPENDED CEILING Figure 59 Dual E62 N2RU ...

Page 33: ...Installation Manual CMA 794 AEN Page 33 Dual E62 N2RU Accessories Figure 60 Dual E62 N2RU Accessories ...

Page 34: ...ling Bracket I VI 1 Assemble Mounting Bracket I VI with 6 x M3 x 6 screws Figure 62 Attaching Cable Tie to Mounting Bracket 2 Attach nylon cable tie to the Bracket I VI combination Place the Bracket I VI Figure 63 Drilling 3 Holes 1 Drill 3 holes for putting Mounting Bracket I VI ...

Page 35: ... the Bracket I VI 2 3 Ensure the nylon tie hangs down through the hole and 2 x M6 screw threads are in holes of 2 sides Assemble the Bracket II Figure 66 Assemble Bracket II 1 Attach Mounting Bracket II to Mounting Bracket V using 4 x M5 x 14 screws Note Paired Mounting Bracket III is already assembled into E62 N2RU in factory ...

Page 36: ...t II 2 Note 2 Bracket II are mounted in opposite directions for cooling Assemble the Bracket V Figure 68 Assemble Bracket V 1 Assemble Mounting Bracket V to Mounting Bracket I using 4 x M6 x 70 screws Flat Washer M6 and Spring Washer M6 Figure 69 Bracket Bottom View ...

Page 37: ...Installation Manual CMA 794 AEN Page 37 Figure 70 Bracket Top View ...

Page 38: ...side of Mounting III Bracket onto Mounting Bracket II Figure 72 Buckle the Bracket 2 Figure 73 SFP Module Insertion 2 Connect the power cable and fiber optical cable to E62 N2RU Note Connect power cable first and then power it on Do NOT connect the powered cable to the E62 N2RU in case of excessive current impulse ...

Page 39: ...Installation Manual CMA 794 AEN Page 39 Figure 74 Wire Connection Diagram Figure 75 Wire Cabling View ...

Page 40: ... to interlace with the hook at the Bracket II Figure 77 Tighten the Screws 4 Tighten the M3 x 3 screws To Perform Maintenance on the E62 N2RU Figure 78 Unlock Rotary Hook Diagram 1 1 Depress the hook on the front of the E62 N2RU to expose the top panel of E62 N2RU for debugging and maintenance ...

Page 41: ...llation Manual CMA 794 AEN Page 41 Figure 79 Top Panel of E62 N2RU Exposed Install Outer Case Figure 80 Sleeve the Outer Case 1 Sleeve the outer case Figure 81 Tighten the Screws 2 Tighten the M3 x 10 screws ...

Page 42: ...age 42 E62 N2RU MOUNTING DIMENSION SPACING Figure 82 E62 N2RU Clearance Figure 83 Dual E62 N2RU Clearance Note 2 x E62 N2RU installed in one spot are directional for case installation and cooling Details in Installation of the E62 N2RU ...

Page 43: ...d including interference that may cause undesired operation Part20 Warning Note This product has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This product generates uses and can radiate radio frequency energy and ...