Corning Restricted
C o r n in g O pt ic a l Com m un ic at io ns
Us e r Man u al I C MA - 4 82 - A E N I P a g e 3 4
4.3.1
Standard Standoff Mount Installation
Note the following:
•
The installation procedure for the standoff mount provided with the RAU5x refers to wall and concrete ceiling installations.
•
When mounting the bracket on a wall the captive screw (indicated in Figure 4-1) should always be positioned in the same
direction as the RAU5x connectors.
•
In wall-mount installations the connectors should face downwards.
•
If installing above acoustic ceiling, allow for at least one inch above the acoustic ceiling for air flow cooling.
Figure 4-1.Examples of Concrete Ceiling Installation of Mounting Bracket: RAU5x without External Antenna; RAU5x with
RxU67 cavity filter.
4.3.1.1
Mount the standoff mount
1. Remove the mount from the RAU5x underside and use to mark and drill appropriate holes for mounting the bracket on the
wall or concrete ceiling. Refer to Appendix C for bracket dimensions.
2. Any of the applicable screw holes can be used.
3. Drill the appropriate screws (not provided) through the bracket installation holes and secure to surface.
Note: The RAU5x connectors should face the standoff mount captive screw.
Figure 4-2. Example of Standoff Mount Installation on Wall