Use an optical power meter and light source for checking the fiber optic cables
•
Make sure the environment is clean while connecting/splicing fiber optic cables
•
All fiber optic connectors should be cleaned prior to connecting to the system
•
Fiber connector protective caps should be installed on all non-terminated fibers and removed just before they are
terminated.
•
LC APC connectors
– ensure that you hear a “click”, indicating a secure connection
•
Never look directly into the end of a fiber that may be carrying laser light. Laser light can be invisible and can damage your
eyes.
3.8 Power Safety Instructions
SAFETY WARNINGS
•
When installing or selecting the power supplies:
•
Be sure to disconnect all power sources before servicing.
•
Calculate the required power according to the requirements of the specific installation and then determine the
configuration of the power supplies. The required DC cables will then be determined by the selected power supply
configuration.
•
Use only UL approved power supplies
•
AC and DC power supply cables
– only use the power cords supplied with the units
•
Install external over-current protective devices for the system according to the requirements described in section 3.4.6.
Types of Power Supplies
Corning supplies various enclosed power supplies (i.e., ICU and PSU6) that can be installed in a rack or mounted on a wall,
depending on your configuration.
.