X75 Fusion Splicer
Parameters and Programs
Operating Instructions
revision: 06/01
3-9
Service Data
Open menu: –› parameter menu –› options / languages –› service data.
Parameter
Significance
Values (default)
Operating Hours
Total number of operating hours
-
Splices
Total number of splices
-
Cleaning Cycle
Number of splices performed before opera-
tor is reminded to clean the electrodes
50 to 700 in steps of 10,
500
Reset Counter:
XX
Reset “Cleaning cycle” counter to 0
yes/no
Replacement
Interval
Number of splices performed before opera-
tor is reminded to replace the electrodes
700 to 7000 in steps of
100, 5000
Reset Counter:
XXX
Reset “Replace Electrodes” counter to 0
yes/no