Video digitizer error
Video system electronics not
functioning.
Switch off the fusion splicer
and switch it back on again. If
the error occurs again, the
fusion splicer must be repaired
at the service center.
You can continue working with
manual fiber alignment.
Error Messages
during Splice
Loss Estimation
Fiber not detected
Contaminated optical system.
Remove contamination and
coating residue from the pro-
tection glass at the optical sys-
tem, see »Cleaning and
Replacing the Protection
Glass« on page 6-15.
Condensation at optical sys-
tem.
The fiber image display is
unclear in one or two axes.
Prevent condensation by plac-
ing the fusion splicer in a room
that is not too cold prior to use.
Only leave the electrode flap
open as long as absolutely
necessary during splicing.
Fiber end is no longer
detected as such by the video
system (fibers burnt or bubble
formation).
Repeat splice.
Error Message
Possible Cause
Remedy