Operating Instructions
revision: 06/01
X75 Fusion Splicer
Troubleshooting and Maintenance
6-18
Cleaning and
Replacing the
Electrodes
The fusion process causes the electrodes to become contaminated. If they become exces-
sively contaminated, they can no longer function properly. The electrodes function prop-
erly:
•
when the arc burns regularly, and
•
when no hissing sounds are audible during the fusion process.
NOTE
The electrode tips may not be bent or broken. The two electrodes are identical.
Replacing the
Electrodes
-
Switch the fusion splicer off and disconnect it from the power supply. If the attachment
power supply is used take out the battery 2.3 Ah. The fusion splicer automatically
cleans the electrodes by means of burnout when it is switched on.
DANGER
The fusion splicer must remain disconnected from the power supply until both elec-
trodes have been correctly installed. The fusion splicer will be damaged if a electrode
cleaning arc is triggered without correctly installed electrodes.