uniform finish, lap each strok­e over the preceding strok­e, 
mak­ing sure the spray is smooth and wet.

Using  the  lowest  possible  atomizing  air  pressure  will  
reduce overspray and provide maximum efficiency.

Proper  handling  of  the  gun  is  essential  for  obtaining  a 
good finish. The gun should be held at a right angle to 
the  surface  being  covered,  and  moved  parallel  with  it. 
For precise control of the gun and material, the trigger 
should be released before the end of the strok­e. 

Hold the gun from  6 to 12 inches away from the surface 
depending  on  material  and  atomizing  pressure.  For  a 

Light Coat

Heavy Coat

Start
strok­e

Pull
trigger

Release 

trigger

End of 
Strok­e

WRONG

RIGHT

Even and wet coat

6 to 12 inches

spray gUN

1. Submerge the front end of the gun in solvent just until  
  the fluid connection is covered.
2. Paint that has built up on the gun should be removed  
  using a bristle brush and solvent.
. Never  submerge  all  of  the  spray  gun  in  solvent  
  because:
  •  This  will  dissolve  the  lubricant  in  the  leather  
    pack­ings and on wear surfaces, causing them to dry  
    out  and  resulting  in  difficult  operation  and  
    faster wear.
  •  Air  passages  in  the  gun  will  become  clogged  with  
    dirty solvent.
4. Using  a  rag  moistened  with  solvent,  wipe  down  the  
  outside of the gun.
5. Oil  gun  daily.  Use  a  drop  of  lightweight  machine  
  oil on:
  A. fluid needle pack­ing
  B.  air valve pack­ing
  C.  trigger pivot point

See Fig. 1 for Location of  
Above Points.

6. Caution: Do not use lubricants  
  which contain silicone. Silicone  
  may cause defects in the  
  finish application.

air NOZZLE, FLUiD NOZZLE,  

air vaLvE assEMBLy

1. All nozzles and needles are made to exact standards.  
  They should be handled carefully.
2. To  clean  nozzles,  immerse  them  in  solvent  until  any  
  dried material is dissolved, then blow them clean. 
. Do not use metal or sharp instrument to probe any of  
  the holes in the nozzles. 
4. Air flow should occur before fluid-flow when the gun  
  is  triggered.  It  may  be  necessary  to  adjust  the  fluid  
  control screw  to mak­e sure air flows before fluid.
5. Do not alter the gun in any way.

gravity FEED

Turn off air supply. Remove cover of cup. Empty the cup 
of material. Clean the cup and cover. Add some cleaning 
solvent to cup. Replace cup cover. Turn on air supply and 
spray  with  proper  cleaning  solvent.  Repeat  with  clean 
solvent  if  necessary.  Remove  solvent,  disconnect  gun,  
remove cup cover and clean. Wipe gun and cup with rag 
dampened with solvent.

CaUtiON…

To  avoid  cross-threading,  all  spray  gun  parts  should  be 
screwed in hand tight initially. If the parts can not easily 
be turned by hand , be sure  you have the correct parts, 
unscrew,  realign,  and  try  again.  NEVER  use  excessive 
force in matching parts.

CLEANING & MAINTENANCE

OPERATION

Fig. 1

a

B

C

Summary of Contents for PSG-1400

Page 1: ...PSG 1400 Rev 07 24 07 Operating Instructions Warning Information Parts Breakdown psg 1400 Gravity Feed Spray Gun and Cup ...

Page 2: ...levels can cause per ma nent hear ing loss Protect your self from noise Noise levels vary with work sur face Wear ear pro tec tors When possible secure work with clamps or vise so both hands are free to op er ate tool Repetitive work motions awk ward po si tions and ex po sure to vibration can be harm ful to hands and arms Avoid inhaling dust or han dling de bris from work processes which can be h...

Page 3: ...to the spray gun Therefore always mount the oil and water extractor at a point in the air supply system where the compressed air temperature is lowest Drain air lines properly Pitch all air lines back towards the com pres sor so that con densed mois ture will flow back into the air receiver where it can be drained off Each low point in an air line acts as a water trap Such points should be fitted ...

Page 4: ...er ti cal fan shaped pat tern which gives max i mum even ma te ri al coverage as the gun is moved back and forth par al lel to the sur face being fin ished Spray pattern may be in fi nite ly adjusted from round to flat Set atomization pressure at no more than 50 PSI For op ti mum per for mance some ma te ri als may spray better at PSI ratings below 50 If unsure always test at PSI ratings before us...

Page 5: ... outside of the gun 5 Oil gun daily Use a drop of lightweight machine oil on A fluid needle packing B air valve packing C trigger pivot point See Fig 1 for Location of Above Points 6 Caution Do not use lubricants which contain sil i cone Sil i cone may cause defects in the finish ap pli ca tion AIR NOZZLE FLUID NOZZLE AIR VALVE ASSEMBLY 1 All nozzles and needles are made to exact stan dards They s...

Page 6: ...e and body C Loose or defective swivel nut on siphon cup Fluid leakage from packing nut A Packing nut loose B Packing worn or dry A Tighten but not so tight as to grip needle B Replace packing or lubricate Dripping from fluid tip A Dry packing B Sluggish needle C Tight packing nut D Worn fluid nozzle or needle A Lubricate B Lubricate C Adjust D For pressure feed replace with new fluid nozzle and n...

Page 7: ...7 RS1708 RS1709 RS1710 RS1716 1 3 RS1726 RS1733 RS1715 RS1720 RS1714 RS1711 PSG 600CC PSG RS1729AL 1 5 Pack RS9612N 0 RS1717 RS1718 RS1719 Optional Nozzle Kits Available PSG 1400 1 3 9004 1 3 1 3mm PGS 1400 1 4 9004 1 4 1 4mm PSG 1400 1 7 9004 1 7 1 7mm PSG 1400 2 0 9004 2 0 2 0mm Nozzle Kits consist of 1 Air Cap 1 Fluid Needle 1 Fluid Nozzle 1700RK Includes all parts as asterisked on parts diagra...

Page 8: ...or a period of 1 year to the con sum er We will repair any air tool covered under this warranty which proves to be defective in mate rial or work man ship during the warranty period In order to have your tool repaired return the tool to any Cornwell Au tho rized Warranty Center freight pre paid Please include a copy of your proof of pur chase and a brief de scrip tion of the prob lem The tool will...

Reviews: