the ACU needs RPM data. The front control unit sub-
stitutes itself to broadcast RPM data.
Fault Code Diagnostics
Front Control Unit (FCU) (MID 146) J1587 Fault Codes by SID
SID
FMI
Fault Description
Action
001
03
CDTC sensor: voltage above
normal, shorted high, or open
circuit
See CDTC Temperature Sensor Circuit Test table, in
, for diagnosis.
04
CDTC sensor: voltage below
normal, shorted low
See CDTC Temperature Sensor Circuit Test table, in
, for diagnosis.
002
03
Evap temp sensor: voltage above
normal, shorted high, or open
circuit
See Evaporator Temperature Sensor Circuit Test table, in
, for diagnosis.
04
Evap temp sensor: voltage below
normal, shorted low
See Evaporator Temperature Sensor Circuit Test table, in
, for diagnosis.
005
05
Recirc/OSA door actuator: current
below normal or open circuit
See Actuator Circuit Test table, in
, for diagnosis.
06
Recirc/OSA door actuator: current
above normal or circuit shorted to
ground
See Actuator Circuit Test table, in
, for diagnosis.
006
05
Mode door actuator: current below
normal or open circuit
See Actuator Circuit Test table, in
, for diagnosis.
06
Mode door actuator: current above
normal or circuit shorted to ground
See Actuator Circuit Test table, in
, for diagnosis.
009
05
Temperature control door: current
below normal or open circuit
See Actuator Circuit Test table, in
, for diagnosis.
06
Temperature control door: current
above normal or circuit shorted to
ground
See Actuator Circuit Test talbe, in
, for diagnosis.
010
02
Blower motor: output data erratic or
intermittent
The FCU compares the analog output signal (speed signal) with
what it thinks it should be. If determined to be in error, this fault
will become active. To diagnose:
1.
Disconnect blower motor. If fault is no longer active, replace
the blower motor. If still active, go to step 2.
2.
Disconnect the blower speed signal output wire (pin A11)
from the FCU connector. Make sure connector is plugged into
FCU after removing wire. If fault is no longer active, check for
short to power or short to ground on output wire. If fault is
still active, replace FCU.
12
Blower motor: bad component,
speed is invalid or incorrect
This fault can occur if the blower speed feedback differs from the
speed control signal being sent by the FCU. See Diagnosis for
Blower Speed is Not Available table, in
Heater and Air Conditioner Troubleshooting
83.00
Fault Code Driven Diagnosis