Actuator Circuit Test
Test
No.
Test
Test Procedure
Test Result
Action
3
Check for short to
ground on return side
of actuator.
For code
146s005 05
(front unit)
disconnect all three actuator
connectors and the FCU
connector. At the recirc actuator
connector, check continuity
between connector pin 3 and
ground. Repeat for pins 4, 5, and
6.
For code
146 s006 05
(front unit)
disconnect all three actuator
connectors and the FCU
connector. At the mode actuator
connector, check continuity
between connector pin 3 and
ground. Repeat for pins 4, 5, and
6.
For code
146 s009 05
(front unit)
disconnect all three actuator
connectors and the FCU
connector. At the temperature
actuator connector, check
continuity between connector pin
3 and ground. Repeat for pins 4,
5, and 6.
For code
200 s009 05
(auxiliary
unit) disconnect the temperature
actuator connector and the ACU
connector. At the temperature
actuator connector, check
continuity between connector pin
3 and ground. Repeat for pins 4,
5, and 6.
NOTE: See
, and
Continuity to ground on
any pin.
Locate short to ground, repair as
necessary, then
go to test no.
9
.
No continuity to ground
on any pin.
Go to test no. 4
.
Heater and Air Conditioner Troubleshooting
83.00
Symptom Driven Diagnosis
122SD and Coronado Workshop Manual, Supplement 9, June 2014
350/17