Actuator Circuit Test
Test
No.
Test
Test Procedure
Test Result
Action
5
Check actuator.
For code
146s005 05
(front unit)
perform "Actuator Stepper Motor
Electrical Test" on the recirc
actuator.
For code
146 s006 05
(front unit)
perform "Actuator Stepper Motor
Electrical Test" on the mode
actuator.
For code
146 s009 05
(front unit)
perform "Actuator Stepper Motor
Electrical Test" on the
temperature actuator.
For code
200 s009 05
(auxiliary
unit) perform "Actuator Stepper
Motor Electrical Test" on the
temperature actuator (auxiliary
unit).
Actuator okay.
Replace FCU/ACU, then
go to
test no. 9
.
Actuator not okay.
Replace actuator, then
go to test
no. 9
.
6
Check actuator return
circuits for open.
For all three active codes at the
same time,
146 s005 05
,
146
s006 05
,
146 s009 05
,
disconnect all three actuator
connectors and the FCU
connector. At each actuator
connector, check continuity
between the following connector
pins:
A2
B1
B2
B3
FCU
3
4
5
6
Actuator
f040620
07/02/2002
NOTE: See
, and
Continuity on all pin
combinations.
Go to test no. 7
.
No continuity on one or
more pin combinations.
Locate open circuit, repair as
necessary, then
go to test no.
9
.
7
Check actuator return
circuits for short to
ground.
Disconnect all three actuator
connectors and the FCU
connector. At the FCU connector,
check continuity between pin A2
and ground. Repeat for pins B1,
B2, and B3.
NOTE: See
, and
Continuity to ground on
any pin.
Repair short to ground, then
go
to test no. 9
.
No continuity to ground
on any pin.
Replace FCU, then
go to test
no. 9
.
Heater and Air Conditioner Troubleshooting
83.00
Symptom Driven Diagnosis
122SD and Coronado Workshop Manual, Supplement 9, June 2014
350/19