Installing the dehumidifier and its connections
Note that any electrical installations carried out in connection with this work must be
done by a qualified electrician in accordance with local and national regulations.
CTR STD-TT must be connected to an earthed, single phase 230VAC/50 Hz socket with a
maximum 16A fuse. An earth-fault breaker is recommended with consideration of the
environment in the crawl space
.
The following instructions are based on using the TT Multi installation kit. Images and diagrams
contain parts from this product.
Outside the house:
Install the wall plate with the pipe in through the hole in the foundation wall that was made for this
purpose, or that possibly was there from before. Secure the plate with screw and plug from the
installation kit.
Install the 45° pipe bend with protective grille and turn it in the desired direction. Check that the
outlet is clear and not too close to the ground, so that the air flow is not obstructed by vegetation,
leaves in the autumn and snow in the winter. The pipe must be bent downwards or diagonally
downwards to prevent rain penetrating the space and entering the hose that is installed on the
inside.