Capacity mode
Indicates the
selected capacity
mode, Max, Eco or
ΔX.
SuperVision
Appears when the
machine is
connected to
Supervision for
remote monitoring
and remote control.
Network status
”Master” or ”slave”
If the machine is
connected to a local
network this mode is
indicated if the machine
controls the network
(Master), or if it is
controlled by another
machine and thus is
Slave.
Timer
Indicates when the
machine is set to
timer mode.
Slave
–
indicates
that the machine is
being controlled by
another machine.
Alarms
The machine has
detected a fault.
Drying indicator
Moves when drying is
in progress and during
defrosting. Also shows
the start delay as well
as alarm symbol in the
event of high/low
ambient temperatures.
Fan indicator
Moves when the
fan is running.
Fan mode
Cont
–
continuous
fan.
If this information
does not appear,
the fan only runs
when drying is
required.
Control mode
Indicates how drying is
controlled, if it is
continuous (MAN =
manual) or if it works to
a preset setpoint for
Relative Humidity (RH),
Mixing ratio (X), or dew
point (DP). It can also be
controlled from an
external hygrostat
(HYG).
If an external sensor for
relative humidity and
temperature is used,
E.RF, E.X or E.DP appears
in this mode.
Additional heater
(ESX product family)
Appears when extra
heater is activated.
The symbol moves
when the extra
heater is connected.
Setting setpoint
The left and right
buttons below the
screen are used to
increase and
decrease the
setpoint that is
shown against a
black background.